TM-V71A/ TM-V71E INSTRUCTION MANUAL 144/440 MHz FM DUAL BANDER

Contents

PREPARATION
SUPPLIED ACCESSORIES
MOBILE INSTALLATION
POWER CABLE CONNECTION
ANTENNA CONNECTION
FRONT PANEL ORIENTATION
ACCESSORY CONNECTIONS
GETTING ACQUAINTED
FRONT PANEL TEXT DESCRIPTION
FRONT PANEL
DISPLAY
REAR PANEL TEXT DESCRIPTION
REAR PANEL
SUB-PANEL
MICROPHONE (MC-59)
BASIC OPERATIONS
SWITCHING THE POWER ON/ OFF
ADJUSTING THE VOLUME
ADJUSTING THE SQUELCH
SELECTING A BAND
SELECTING DUAL BAND MODE/ SINGLE BAND MODE
SELECTING A FREQUENCY BAND
SELECTING AN OPERATING MODE
TRANSMITTING
MENU MODE
MENU ACCESS
MENU CONFIGURATION
CHARACTER ENTRY
OPERATING THROUGH REPEATERS
REPEATER ACCESS
TRANSMITTING A 1750 Hz TONE
REVERSE FUNCTION
AUTOMATIC SIMPLEX CHECKER (ASC)
TONE FREQUENCY ID
MEMORY CHANNELS
SIMPLEX & REPEATER OR ODD-SPLIT MEMORY CHANNEL?
STORING SIMPLEX AND STANDARD REPEATER FREQUENCIES
STORING ODD-SPLIT REPEATER FREQUENCIES
RECALLING A MEMORY CHANNEL
CLEARING A MEMORY CHANNEL
NAMING A MEMORY CHANNEL
SWITCHING THE MEMORY NAME/ FREQUENCY DISPLAY
MEMORY-TO-VFO TRANSFER
CHANNEL DISPLAY FUNCTION
PROGRAMMABLE MEMORY (PM)
APPLICATION ExAMPLES
STORING DATA IN PM CHANNELS
RECALLING PM CHANNELS
AUTO PM CHANNEL STORE
PM CHANNEL RESET
SCAN
SELECTING A SCAN RESUME METHOD
VFO SCAN
MEMORY SCAN
GROUP SCAN
PROGRAM SCAN
MHz SCAN
CALL SCAN
CONTINUOUS TONE CODED SQUELCH SYSTEM (CTCSS)
USING CTCSS
CTCSS FREQUENCY ID
DIGITAL CODED SQUELCH (DCS)
USING DCS
DCS CODE ID
DUAL TONE MULTI-FREQUENCY (DTMF)
MANUAL DIALING
AUTOMATIC DIALER
DTMF KEY LOCK
EchoLink®
WHAT IS EchoLink?
STORING EchoLink MEMORY
SETTING UP EchoLink Sysop MODE
AUXILIARY FUNCTIONS
POWER-ON MESSAGE
DISPLAY BRIGHTNESS
KEY LOCK
KEY BEEP
PROGRAMMABLE VFO
CHANGING THE FREQUENCY STEP SIZE
PROGRAMMABLE FUNCTION KEYS
FREQUENCY DIRECT ENTRY
AUTOMATIC POWER OFF (APO)
S-METER SQUELCH
ADVANCED INTERCEPT POINT (AIP)
SWITCHING FM/AM MODE
BEAT SHIFT
SPEAKER MUTE
SELECTING AN OUTPUT POWER
TIME-OUT TIMER (TOT)
ExTERNAL SPEAKER CONFIGURATION
MASKING A BAND
DISPLAY PARTITION BAR
WEATHER ALERT (K TYPE MODELS ONLY)
POWER ON PASSWORD
VGS-1 OPTIONAL VOICE GUIDE & STORAGE UNIT
VOICE ANNOUNCEMENTS
VOICE RECORDER
CROSS-BAND/ LOCKED-BAND OPERATION (K TYPE MODELS ONLY)
REPEATER HOLD
REPEATER ID
PACKET OPERATION
DATA BAND
DATA TERMINAL SPEED
PC PORT SPEED
SQC OUTPUT SETTING
WIRELESS OPERATION (K TYPE MODELS ONLY)
PREPARATION
CONTROL OPERATION
TRANSCEIVER RESET
OPTIONS
MEMORY CONTROL PROGRAM MCP-2A
CONNECTING THE PG-5G/ PG-5H INTERFACE CABLES
INSTALLING THE DFK-3D PANEL KIT
CONNECTING THE PG-5F ExTENSION CABLE
INSTALLING THE VGS-1 UNIT
MAINTENANCE
GENERAL INFORMATION
SERVICE
SERVICE NOTE
CLEANING
TROUBLESHOOTING
SPECIFICATIONS

The following links are to sections that were originally at the front of the manual.
MANUAL FRONT COVER
THANK YOU
FEATURES
NOTICE TO THE USER
INFORMATION TO THE DIGITAL DEVICE USER
WHEN CONDENSATION OCCURS INSIDE THE TRANSCEIVER
WARNING!
PRECAUTIONS
CAUTION!
WARNING!
DISCLAIMER AND NOTES FROM THE AUTHOR


PREPARATION

Supplied Accessories

Note: A type code (K, E, or M4) can be found on the label attached to the package box.

Item
Part Number
Quantity
Microphone
T91-0657-XX
1
DC power cable(with 20 A fuses) K, M4 types
E30-7628-XX
1
DC power cable(with 20 A fuses) E type
E30-3452-XX
1
Mounting bracket
J29-0628-XX
1
Screw set
N99-0331-XX
1
Fuse (15 A) K, M4 types
F51-0079-XX
1
Fuse (15 A) E type
F52-0024-XX
1
Warranty Card K, E types only
-
1
Instruction manual
B62-1926-XX
1

 

MOBILE INSTALLATION

Select a safe, convenient location inside your vehicle that will minimize danger to
your passengers and yourself while the vehicle is in motion. Consider installing
the transceiver under the dash in front of the passenger seat so that knees or legs
will not strike the radio during sudden braking of your vehicle. Try to pick
a well-ventilated location that is shielded from direct sunlight.
Note: You may experience interference on your GPS receiver when using in or around 438.8 MHz
(A band) and/or 443.8 MHz (B band). To eliminate the interference, ensure that the transceiver is
installed at a location separate from your GPS receiver.
1 Install the mounting bracket in the vehicle using the supplied self-tapping
screws and flat washers (4 of each are supplied).
· The bracket can be mounted with the bracket opening facing down, for under dash
mounting, or facing up.
· The bracket must be installed so that the 3 screw slots on the edge of each bracket
side are facing the back.
Self-tapping screw (5 x 6 mm)and Flat washer
2 Position the transceiver, then insert and tighten the supplied hexagon SEMS
screws and flat washers (4 of each are supplied, 2 for each side of the bracket).
· Ensure that all hardware is tightened, to prevent vehicle vibration from loosening the
bracket or transceiver.
SEMS screw (M4 x 0 mm)
· Set an appropriate angle for the main unit, using the 3 screw slots on the rear edge
of each bracket side.

POWER CABLE CONNECTION

Mobile Operation

Be sure to use a 12V vehicle battery that has sufficient current capacity. If
the current to the transceiver is insufficient, the display may darken during
transmission or the transmit output power may drop excessively. Never
connect the transceiver to a 24V battery
Note: If you use the transceiver for a long period when the vehicle battery is not fully charged
or when the engine is OFF, the battery may become discharged and will not have sufficient
reserves to start the vehicle. Avoid using the transceiver under these conditions.
1 Route the DC power cable supplied with the transceiver directly to the
vehicle's battery terminals using the shortest path from the transceiver.
· When using a noise filter, it should be installed with an insulator to prevent it from
touching metal on the vehicle.
· We do not recommend using a cigarette lighter socket as some cigarette lighter
sockets introduce an unacceptable voltage drop.
· If the power cable must be routed through a hole in the vehicle chassis or body,
for example in the firewall at the front of the passenger compartment, use a
rubber grommet to protect the cable from abrasion. Dismantle the fuse holder to
pass the cable through the firewall.
· The entire length of the cable must be dressed so it is isolated from heat,
moisture, and the engine secondary (high voltage) ignition system/ cables.
2 After the cable is in place, wind heat-resistant tape around the fuse holder
to protect it from moisture. Tie down the full run of cable.
3 To prevent the risk of short circuits, disconnect other wiring from the
negative (-) battery terminal before connecting the transceiver.
4 Confirm the correct polarity of the connections, then attach the power cable
to the battery terminals; red connects to the positive (+) terminal and black
connects to the negative (-) terminal.
· Use the full length of the cable without cutting off excess, even if the cable is
longer than required. In particular, never remove the fuse holders from the cable.
5 Reconnect any wiring removed from the negative terminal.
6 Connect the DC power cable to the transceiver.
· Press the connectors firmly together until the locking tab clicks.

Fixed Station Operation

In order to use this transceiver for fixed station operation, you will need a
separate 13.8V DC power supply that must be purchased separately. The
recommended current capacity of the power supply is 12 A.
Note: Do not plug the DC power supply into an AC outlet until you make all connections.
1 Ensure that the transceiver and DC power supply are both OFF.
2 Connect the DC power cable to the regulated DC power supply and ensure
that the polarities are correct (Red: positive, Black: negative).
· Use the supplied DC power cable to connect the transceiver to a regulated
power supply. Do not directly connect the transceiver to an AC outlet.
· Do not substitute the cable with smaller gauge wires.
3 Connect the DC power cable to the transceiver.
· Press the connectors firmly together until the locking tab clicks.
Note: For your transceiver to fully exhibit its performance capabilities, we recommend using
an optional PS-33 (20.5 A, 25% duty cycle) power supply.

Replacing Fuses

If the fuse blows, determine the cause, then correct the problem. After the
problem is resolved, replace the fuse. If newly installed fuses continue to
blow, disconnect the power cable and contact your authorized Kenwood
dealer or an authorized Kenwood service center for assistance.

Fuse Location
Fuse Current Rating
Transceiver (located on the DC connector)
15 A
Supplied DC power cable
20A

Only use fuses of the specified type and rating; otherwise the transceiver could be damaged.

ANTENNA CONNECTION

Before operating, you must first install an efficient, well-tuned antenna. The
success of your installation will depend largely on the type of antenna and its
correct installation. The transceiver can give excellent results if the antenna
system and its installation are given careful attention.
Use a low-loss coaxial feed line that also has a characteristic impedance of
50 ohms, to match the transceiver input impedance. Coupling the antenna to the
transceiver via feed lines having an impedance other than 50 ohms reduces the
efficiency of the antenna system and can cause interference to nearby broadcast
television receivers, radio receivers, and other electronic equipment.
Transmitting without first connecting an antenna or other matched load may damage the
transceiver. Always connect the antenna to the transceiver before transmitting.
All fixed stations should be equipped with a lightning arrester to reduce the risk of fire, electric
shock, and/or transceiver damage.

FRONT PANEL ORIENTATION

This transceiver allows you to change the orientation of the front panel.
Depending on where/how you installed the transceiver you may wish to flip the
front panel upside-down for easier operation.
1 On the right side of the front panel, pull the panel release latch forward.
2 Slide the front panel to the left, then pull it away from the main body of the transceiver.
3 Flip the front panel upside-down, then reattach it to the main body of the transceiver.

ACCESSORY CONNECTIONS

External Speakers

If you plan to use external speakers, choose speakers with an impedance of
8 ohms. The external speaker jacks accept a 3.5 mm (1/8") mono (2-conductor)
plug. We recommend using SP-50B speakers.
There are 2 speaker jacks on the rear of the transceiver: SP 1 and SP 2.
Refer to "External Speaker Configuration" to determine how the speakers will be used.

Microphone

To communicate using voice, connect the supplied microphone to the MIC jack
on the left side of the transceiver. Press firmly on the plug until the locking tab clicks.

GETTING ACQUAINTED

FRONT PANEL TEXT DISCRIPTION

Starting at the upper left corner and working down then across the bottom from left to right and finally up to the upper right corner:
Button labeled "VFO" with "M.V" text above it
Button labeled "MR" with "M.IN" text above it
In the lower left corner is a rotary control labeled "MNU"
Seven buttons across the bottom from left to right
Button labeled "CALL" with "C.IN" text above it
Button labeled "F" with a graphic of a key above it
Button labeled "TONE" with "T.SELIN" text above it
Button labeled "REV" with "SHIFTIN" text above it
Button labeled "LOW" with "MUTE" text above it
Button labeled "PF1"
Button labeled "PF2"
Next are two dual rotary controls at the lower right
Above the right-most rotary control is a button labeled "PM" with "PM.IN" text above it
Above that button at the top right is the Power button


FRONT PANEL

VFO

Press [VFO] to enter VFO mode, then rotate the Tuning control to
select an operating frequency. Press [VFO](1s) to start VFO scan.
Press [F],[VFO] to copy the current Memory channel or Call channel
to the VFO (memory shift).

MR

Press [MR] to enter Memory Channel mode, then rotate the Tuning
control to select a Memory channel. Press [MR](1s) to start Memory scan.
Select a Memory channel, then press [F],[MR] to store the current
operating frequency in the Memory channel. See MEMORY CHANNELS

TuningControl

Rotate to select an operating frequency or Memory channel, change the scan
direction, select a tone frequency, etc. Press the Tuning control to enter MHz
mode (while in VFO or Call mode) or to toggle the display between the channel
name and frequency (while in Memory Channel mode). Press [F], then press
the Tuning control to enter Menu mode. Press the Tuning control
(1s) to start MHz scan or Group scan.

CALL

Press [CALL] to select the Call channel. Press [CALL](1s) to start Call scan.
Press [F],[CALL] to store the current operating frequency to the Call channel.

F

Press [F] to enter Function mode. Press [F](1s) to turn the transceiver
Key Lock function ON or OFF.

TONE

Press [TONE] to turn the Tone function ON. Continually press [TONE] to
toggle the functions as follows: Tone ON >> CTCSS ON >> DCS ON >> OFF.
While Tone, CTCSS, or DCS is ON, press [F],[TONE] to enter CTCSS or
DCS setup mode.

REV

Press [REV] to turn the Reverse function ON or OFF. Press [REV] (1s)
to turn the Automatic Simplex Checker ON. Press [F],[REV]
to enter Offset Direction selection mode. Each time you press [F],[REV], the
offset direction toggles as follows:
plus (+) direction -> minus (-) direction -> -7.6 MHz (E type only) -> OFF.

LOW

Press [LOW] to toggle the transmit output power as follows: High Power (K,
E types only) -> Middle Power -> Low Power. Press [F],[LOW] to
turn the Mute function ON or OFF.

PF1

Press [PF1] to activate its programmable function. The default
function is "Frequency Band Select".

PF2

Press [PF2] to activate its programmable function. The default
function is "Operation Band Select".

BANDSEL(VOL)Control

Rotate the [BANDSEL] control to adjust the speaker volume.
Press the left [BANDSEL] to select the A band. Press the right [BANDSEL]
to select the B band. Press [BANDSEL](1s) to toggle between single and
dual-band mode.

SQLControl

Rotate the [SQL] control to adjust the squelch level. Clockwise opens the
squelch and counterclockwise tightens the squelch.

PM

Press [PM] to enters the PM (Programmable Memory) channel selection mode.
Press [F],[PM] to enter PM Channel registration mode.

Power button

Press [Power button] to turn the transceiver power ON and OFF.

DISPLAY

Table of display graphics and their location and meaning within the display LCD has been omitted in this document.

REAR PANEL TEXT DESCRIPTION

Left to right:
Antenna SO-239 connector
Cooling fan
6 pin DIN DATA connector
8 pin DIN PC connector
Below those two DIN connectors are:
Speaker 2, a 1/8" 2 conductor jack closest to cooling fan)
Speaker 1, a 1/8" 2 conductor jack

REAR PANEL

ANT

Connect an M-type (TM-V71A) or N-type (TM-V71E) external antenna to this
terminal. When making test transmissions, connect a dummy load in
place of the antenna. The antenna system or load should have an impedance of 50 ohms.

DATA

Connect a TNC unit to this terminal, via a 6-pin mini DIN connector.

PC

Connect a personal computer to this terminal, via an -pin mini DIN connector.

SP(SP1/SP2)

If desired, connect 1 or 2 external speakers for clearer audio. These jacks
accept 3.5 mm (1/") diameter, 2-conductor plugs.
Refer to "External Speaker Configuration" to determine how the speakers will be used.

SUB-PANEL

MIC

Connect the supplied microphone to this jack.

PANEL

When using an optional panel kit, attach the panel to this terminal using the
cable that comes with the panel kit.

MICROPHONE (MC-59)

MicrophoneJack

Pin 1 No Connection
Pin 2 DC 8 V, 100 mA max
Pin 3 GND
Pin 4 PTT
Pin 5 GND (MIC)
Pin 6 MIC, 600 ohms impedance
Pin 7 No Connection
Pin 8 Keypad serial data

PTT switch

Press and hold, then speak into the microphone to transmit.

DTMF keypad

Press these keys to make DTMF calls, enter frequencies, or enter characters.

CALL/A

Functions the same as the transceiver front panel [CALL] key. This is also the
PF4 key and can be reprogrammed with a programmable function.

VFO/B

Functions the same as the transceiver front panel [VFO] key. This is also the
PF3 key and can be reprogrammed with a programmable function.

MR/C

Functions the same as the transceiver front panel [MR] key. This is also the
PF2 key and can be reprogrammed with a programmable function}.

PF/D

Press to toggle between bands A and B. This is also the PF1 key and can be
reprogrammed with a programmable function.

UP/DWN

Functions the same as the transceiver Tuning control.

BASIC OPERATIONS

SWITCHING THE POWER ON/ OFF

Press the [Power ] switch to switch the transceiver ON.
· The power on message momentarily appears on the display.
· If the transceiver power on password has been activated, you must first enter
your password before you can operate the transceiver.
Press the [Power ] switch again to switch the transceiver OFF.

ADJUSTING THE VOLUME

Rotate the [BAND SEL] (VOL) control of your selected band clockwise to
increase the volume and counterclockwise to decrease the volume.
Note: Some functions of this transceiver, such as the beep and voice announcements, have their
own volume settings. Adjust those settings to your desired values.

ADJUSTING THE SQUELCH

Squelch is used to mute the speaker when no signals are present. With the
squelch level set correctly, you will hear sound only while actually receiving a
signal. The higher the squelch level selected, the stronger the signals must be in
order to hear them.
Rotate the [SQL] control of your selected band, when no signals are present, and
select the squelch level at which the background noise is just eliminated.

SELECTING A BAND

Press the left [BAND SEL] control to select band A and the right [BAND SEL]
control to select band B.
· The (GRAPHIC SYMBOL) icon appears at the top of the band on which you are operating and the
icon appears at the top of the band on which you are currently set to transmit.
Band A (left [BAND SEL] control):
Band B (right [BAND SEL] control):
Pressing [PF2] allows you to switch the operating band between bands A and B,
while maintaining the original band as the transmit band.

SELECTING DUAL BAND MODE / SINGLE BAND MODE

You can switch the transceiver between dual band operation and single band
operation by pressing [BAND SEL] (1s) of your selected band.
Note: You can also turn the center partition bar display off.

SELECTING A FREQUENCY BAND

You can change the default frequency bands for bands A and B.
1 Select band A or B by pressing the [BAND SEL] control or [PF2].
2 Press [F], [BAND SEL] of your selected band.
· Each time you press [F], [BAND SEL], you cycle to the next frequency band.
· The default setting of the [PF1] key also allows you to cycle to the next frequency band.
· When masking a band, you are restricted to using only the selectable band.
· When receiving 2 signals on the same band, the image interference, sensitivity, etc., performance will decrease.
· Band A: 118 >> 144 (default) >> 220 >> 300 >> 430/440 (MHz).
· Band B: 144 >> 220 >> 300 >> 430/440 (default) >> 1200 (MHz).
Note:
M4 type models do not have the following frequency bands available:
118, 220, 300, or 1200 (MHz).
E and M4 type models use the 430 MHz band and K type models use the 440 MHz band.
Frequency ranges:
· 118 MHz: 118 ~ 135.995 MHz
· 144 MHz: 136 ~ 199.995 MHz
· 220 MHz: 200 ~ 299.995 MHz
· 300 MHz: 300 ~ 399.995 MHz
· 430/440 MHz: 400 ~ 523.995 MHz
· 1200 MHz: 800 ~ 1299.995 MHz (excluding cellular band)

SELECTING AN OPERATING MODE

There are 3 operating modes available to choose from: VFO mode, Memory Channel mode, and Call Channel mode.

VFO mode
VFO mode allows you to manually change the operating frequency.
1 Press [VFO] to enter VFO mode.
2 Rotate the Tuning control to select your desired operating frequency.
· You can also adjust the frequency by using the microphone [UP]/[DWN] keys.
· The default step frequency for the Tuning control varies according to the type
and operating band:

Type
144 MHz
430/440 MHz
K
5 kHz
25 kHz
E
12.5 kHz
25 kHz
M4
10 kHz
10 kHz

· To adjust the frequency by a larger amount, you can press the Tuning control
to enter MHz mode. While in MHz mode, rotate the Tuning control to adjust the
frequency in steps of 1 MHz. Press the Tuning control again to exit MHz mode
and adjust the frequency using the normal step frequency. Using the MCP-2A
(Memory Control Program), you can set the MHz mode step frequency to 10 MHz.
Pressing the Tuning control will switch between 10 MHz, 1MHz, and off.

Memory Channel mode
Memory Channel mode allows you to quickly select a frequently used
frequency and related data which you have saved in the transceiver memory.
1 Press [MR] to enter Memory Channel mode.
2 Rotate the Tuning control to select your desired Memory channel.

Call Channel mode
Call Channel mode allows you to quickly select a preset channel to allow
immediate calls on that frequency. The Call channel can be conveniently used
as an emergency channel within your group.
1 Select your desired band (A or B).
· The Call channel has a dedicated frequency for both bands A and B. The
default frequency for band A is 144 MHz. The default frequency for band B is
430/440 MHz.
2 Press [CALL] to enter Call Channel mode.
· "C" appears on the display.
3 Press [CALL] again to return to your previous operating frequency.

TRANSMITTING

1 Select your desired band and frequency/channel.
2 Press and hold the microphone [PTT] switch and speak into the microphone to transmit.
· The (graphic symbol) icon and the RF power meter appear on the display for the selected
transmit band. The RF power meter shows the relative transmit output power.
· The (graphic symbol) / icon appears on the display, depending on what output power you have selected.
· Speak into the microphone in your normal voice, while keeping the microphone
approximately 5 cm from your mouth. Speaking too close to the microphone or too
loudly may increase distortion and reduce intelligibility of your signal at the receiving station.
3 When you finish speaking, release the [PTT] switch.

MENU MODE

Many functions on this transceiver are selected or configured through the Menu
instead of physical controls. Once you become familiar with the Menu system,
you will appreciate the versatility it offers.

MENU ACCESS

1 Press [F], Tuning control to access the Menu.
· The Menu name and number appears on the display.
2 Rotate the Tuning control to select your desired Menu.
3 Press the Tuning control to set up the current Menu.
4 Rotate the Tuning control to select your desired value for the selected Menu.
5 Press the Tuning control to set the selected value.
6 Repeat steps 2 to 5 to set up additional Menus.
· Press [F] (ESC) at any time to exit Menu mode.
· Press [TONE] (BACK) at any time to cancel the Menu setup and return to the Menu selection.

MENU CONFIGURATION

Menu No. Display Description Setting Values Default Setting
000 BEEP Beep sound OFF/ ON ON
001 BP.VOL Beep volume level 1 ~ 7 5
002 EXT.SP External speaker output mode MODE 1/ MODE 2 MODE 1
003 Note 1 ANN Voice announcement mode OFF/ AUTO/ MANUAL AUTO
004 Note 1 ANN.LNG Voice announcement language ENG/ JPN ENG
006 Note 1 ANN.SPD Voice announcement speed 0 ~ 4 1
007 Note 1 PLAY.BK Recording playback repeat OFF/ ON OFF
008 Note 1 P.BK.INT Playback repeat interval time 0 ~ 60 (seconds) 10
009 Note 1 CON.REC Conversation recording OFF/ ON OFF
100 PRG.VFO Programmable VFO setup Varies with the selected frequency band ­
101 STEP Step frequency Varies with the selected frequency band ­
102 MODLAT Modulation/demodulation mode Varies with the selected frequency band ­
103 VHF.AIP VHF band AIP OFF/ ON OFF
104 UHF.AIP UHF band AIP OFF/ ON OFF
105 S.SQL S-meter squelch OFF/ ON OFF
106 S.SQ.HNG S-meter squelch hangup time OFF/ 125/ 250/ 500 (ms) OFF
107 MUT.HNG Mute hangup time setup OFF/ 125/ 250/ 500/ 750/ 1000 (ms) OFF
108 B.SHIFT Beat shift OFF/ ON OFF
109 TOT Time-out timer 3/ 5/ 10 (minutes) 10
110 Note 2 WX.ALT Weather alert OFF/ ON OFF
111 Microphone level (New) Low/ Medium/ High Medium
200 Note 3 M.NAME Memory name setup Up to 6 characters ­
201 RECALL Memory channel recall method ALL/ CURRENT ALL
202 Note 3 L.OUT Memory channel lockout OFF/ ON OFF
203 GR.LINK Memory group link registration Up to 10 digits (0 ~ 9) ­
204 ELK.MEM EchoLink memory setting Up to 8 digits for DTMF code ­
205 ELK.SPD EchoLink memory transmission speed FAST/ SLOW FAST
300 DT.HOLD DTMF transmission hold OFF/ ON OFF
301 DT.MEM DTMF memory Up to 16 digits for DTMF code ­
302 DT.SPD DTMF memory transmission speed FAST/ SLOW FAST
303 DT.PAUS DTMF pause code time 100/ 250/ 500/ 750/ 1000/ 1500/ 2000 (ms) 500
304 DT.LOCK DTMF key lock OFF/ ON OFF
400 OFFSET Offset frequency See reference page ­
401 Note 4 ARO Auto Repeater Offset OFF/ ON ON
402 1750.HD Transmission hold when transmitting a 1750 Hz tone OFF/ ON OFF
403 Note 2 RPT.MOD Repeater mode CROSS/ A-TX/ B-TX CROSS
404 Note 2 RPT.HLD Repeater transmission hold ON/ OFF OFF
405 Note 2 RPT.ID Repeater ID registration Up to 6 characters ­
406 Note 2 ID.TX Repeater ID transmission OFF/ MORSE/ VOICE OFF
500 P.ON.MSG Power on message setup Up to 6 characters HELLO
501 BRIGHT Display brightness OFF/ 1 ~ 8 8
502 AUTO.BR Display auto brightness OFF/ ON OFF
503 COLOR Backlight color AMBER/ GREEN AMBER
507 PF1 PF1 key programmable function value See reference page FR.BAND
508 PF2 PF2 key programmable function value See reference page CTRL
509 MIC.PF1 Microphone PF1 key programmable function value See reference page A/B
510 MIC.PF2 Microphone PF2 key programmable function value See reference page MR
511 MIC.PF3 Microphone PF3 key programmable function value See reference page VFO
512 MIC.PF4 Microphone PF4 key programmable function value See reference page CALL (K/ M4 types)
1750 (E types)
513 MIC.LCK Microphone key lock OFF/ ON OFF
514 SC.RESM Scan resume method TO/ CO/ SEEK TO
516 APO Auto Power Off time OFF/ 30/ 60/ 90/ 120/ 180 (minutes) 180
517 DAT.BND Data Band mode A/ B/ ATX.BRX/ ARX.BTX A
518 DAT.SPD Data communications speed 1200/ 9600 (bps) 1200
519 PC .SPD PC terminal baud rate speed 9600/ 19200/ 38400/ 57600 (bps) 9600
520 SQC.SRC SQC output type OFF/ BUSY/ SQL/ TX/ BUSY.TX/ SQL.TX BUSY.TX
521 AUTO.PM Automatic PM entry OFF/ ON ON
522 Note 2 REM.ID Personal Identification Number 000 ~ 999 000
523 Note 2 ANS.BK Answer back OFF/ ON ON
527 DP.BAR Display partition bar OFF/ ON ON
998 PASSWD Power on password OFF/ ON OFF
999 RESET Reset VFO/ PART/ PM/ FULL VFO

Note 1: Menu numbers 03 thru 09 are available only when the optional VGS-1 unit is installed in the transceiver.
Note 2:Menu numbers 110, 403 thru 406, 522, and 523 are available only for K type models.
Note 3:Menu numbers 200 and 202 are available only if a Memory Channel has been stored in the transceiver.
Note 4:Menu number 401 is available only for K and E type models

CHARACTER ENTRY

Certain menus require you to enter characters, such as the power on message
and memory names. When character entry is required, a cursor will appear on the display.
1 Press the Tuning control.
· The cursor will blink.
2 Rotate the Tuning control to select your desired character.
· You can enter characters as described below:
- Power on message, memory name, and repeater ID (K type only): 0 ~ 9, A ~ Z,
-, /, @, and space
- DTMF memory code: 0 ~ 9, A ~ F, and space
- EchoLink memory code: 0 ~ 9, A ~ F
- Memory group link and wireless remote ID (K type only): 0 ~ 9
3 Press the Tuning control to set the selected character.
· The cursor will move to the next digit.
· You can move the cursor to the left or right by pressing [REV] ( ) or [LOW] ( ).
· You can delete the selected character by pressing [PF1] (CLR).
4 Repeat steps 2 and 3 to enter the remaining characters.
· Press [F] (ESC) at any time to exit Menu mode.
· Press [TONE] (BACK) at any time to cancel the Menu setup and return to the Menu selection.

Microphone Keypad character Entry

The microphone keys can also be used to enter characters. Refer to the table
below for characters corresponding to microphone keys.

Key
Character Display (with each press of the key)
1
Q
Z
1
 
2
A
B
C
2
3
D
E
F
3
4
G
H
I
4
5
J
K
L
5
6
M
N
O
6
7
P
R
S
7
8
T
U
V
8
9
W
X
Y
9
0
(space)
0
   
*
Not used
#
-
/
@
 

The microphone [A] ~ [D] keys have special functions assigned to them:
[A]: Functions the same as [PF1] (CLR)
[B]: Functions the same as [REV] ( )
[C]: Functions the same as [LOW] ( )
[D]: Functions the same as the Tuning control

OPERATING THROUGH REPEATERS

Repeaters are often installed and maintained by radio clubs, sometimes with the
cooperation of local businesses involved in the communications industry.
Compared to simplex communication, you can usually transmit over much greater
distances by using a repeater. Repeaters are typically located on mountain tops
or other elevated locations. They generally operate at higher ERP (Effective
Radiated Power) than a typical station. This combination of elevation and high
ERP allows communications over considerable distances.

REPEATER ACCESS

Most repeaters use a receive and transmit frequency pair with a standard or
non-standard offset (odd-split). In addition, some repeaters must receive a tone
from the transceiver in order to gain access to the repeater. For details, consult
your local repeater reference.

Selecting an Offset Direction

The offset direction allows your transmit frequency to be higher (+) or lower (-)
than the receive frequency.
1 Select your desired band (A or B).
2 Press [F], [REV] to select an offset direction.
· Each time you press [F], [REV], the offset direction changes as follows:
Simplex operation >> + >> - >> Simplex operation
· If you are using an E type transceiver, when operating on the 430 MHz band, the
offset direction changes as follows:
Simplex operation >> + >> - >> = (-7.6 MHz) >> Simplex operation
If the offset transmit frequency falls outside the allowable range, transmitting
is inhibited. Use one of the following methods to bring the transmit frequency
within the band limits:
· Move the receive frequency further inside the band.
· Change the offset direction.
Note: While using an odd-split memory channel or transmitting, you cannot change the offset direction.

Selecting an Offset Frequency

The offset frequency is the value which the transmit frequency will be offset
from the receive frequency. The default offset frequency on the 144 MHz
band is 600 kHz for all type versions. The default on the 430/440 MHz band is 5 MHz.
1 Select your desired band (A or B).
2 Enter Menu mode and access Menu 400 (OFFSET).
3 Set the appropriate offset frequency value.
· The selectable range is from 00.00 MHz to 29.95 MHz, in steps of 50 kHz.
Note: After changing the offset frequency, the new offset frequency will also be used by
Automatic Repeater Offset.

Activating the Tone Function

To turn the Tone function on:
1 Select your desired band (A or B).
2 Press [TONE] to turn the Tone function ON.
· Each time you press [TONE], the selection changes as follows:
None >> T (Tone) >> CT (CTCSS) >> DCS (DCS) >> None
· The icon appears on the display when the tone function is ON.
Note: When accessing a repeater that requires a 1750 Hz tone, you do not need to activate
the Tone function. Simply press the key assigned to the 1750 Hz tone to transmit the tone.

Selecting a Tone Frequency

To select the tone frequency required to access your desired repeater:
1 Turn the Tone function ON.
2 Press [F], [TONE].
· The current tone frequency appears on the display. The default frequency is 88.5 Hz.
3 Rotate the Tuning control to select your desired frequency.
· To exit the tone frequency selection, press [F] (ESC).
4 Press any key other than the Tuning control and [F] (ESC) to set the selected frequency.
Note: If you have set up a Memory channel with a tone setting, simply recall the Memory
channel instead of setting up the tone frequency every time.

Tone Number
Frequency (Hz)
01
67.0
02
69.3
03
71.9
04
74.4
05
77.0
06
79.7
07
82.5
08
85.4
09
88.5
10
91.5
11
94.8
12
97.4
13
100.0
14
103.5
15
107.2
16
110.9
17
114.8
18
118.8
19
123.0
20
127.3
21
131.8
22
136.5
23
141.3
24
146.2
25
151.4
26
156.7
27
162.2
28
167.9
29
173.8
30
179.9
31
186.2
32
192.8
33
203.5
34
206.5
35
210.7
36
218.1
37
225.7
38
229.1
39
233.6
40
241.8
41
250.3
42
254.1

 

Automatic Repeater Offset (K and E Types Only)

This function automatically selects an offset direction and activates the Tone
function, according to the frequency that you have selected. To obtain an up-
to-date band plan for repeater offset direction, contact your national Amateur
Radio association.
1 Enter Menu mode and access Menu 401 (ARO).
2 Set the ARO to ON.
3 Press [BAND SEL A] to select the A band.
4 Press [VFO] to select VFO mode.
5 Rotate the Tuning control to select your desired frequency.
6 Press [PTT] to start a call.
· You will be transmitting on an offset frequency value determined from your offset
setting value and an offset direction depending on your selected
frequency. Refer to the settings below for offset directions:
K Type:
Under 145.100 MHz:
No offset (Simplex operation)
145.100 ~ 145.499 MHz: Minus (-) offset
145.500 ~ 145.999 MHz: No offset (Simplex operation)
146.000 ~ 146.399 MHz: Plus (+) offset
146.400 ~ 146.599 MHz: No offset (Simplex operation)
146.600 ~ 146.999 MHz: Minus (-) offset
147.000 ~ 147.399 MHz: Plus (+) offset
147.400 ~ 147.599 MHz: No offset (Simplex operation)
147.600 ~ 147.999 MHz: Minus (-) offset
148.000 MHz and higher: No offset (Simplex operation)
E Type:
Under 145.000 MHz:
No offset (Simplex operation)
145.600 ~ 145.799 MHz: Minus (-) offset
145.800 MHz and higher: No offset (Simplex operation)

TRANSMITTING A 1750 Hz TONE

Most repeaters in Europe require that a transceiver transmit a 1750 Hz tone.
By turning the 1750 Hz tone menu item ON, the transceiver will automatically
transmit the 1750 Hz tone for 2 seconds whenever you transmit.
1 Enter Menu mode and access Menu 402 (1750.HD).
2 Set the tone to ON or OFF.
· When set to ON, the 1750 Hz tone will transmit. When set to OFF, the tone will not be transmitted.

REVERSE FUNCTION

After setting a separate receive and transmit frequency, you can exchange these
frequencies using the Reverse function. This allows you to manually check the
strength of signals you receive directly from other stations, while using a repeater.
If the station's signal is strong, move to a simplex frequency to continue the
contact and free up the repeater.
Press [REV] to turn the Reverse function ON or OFF.
· When the Reverse function is ON, the icon will appear on the display.
Note:
If the transmit frequency is outside the allowable transmit frequency range when using
Reverse, pressing [PTT] will cause an error tone to sound and transmission will be inhibited.
If the receive frequency is outside the receive frequency range when using Reverse, an error
tone will sound and Reverse will not operate.
The ARO (Automatic Repeater Offset) will not function when Reverse is ON.
You cannot switch Reverse ON or OFF while transmitting.

AUTOMATIC SIMPLEX CHECKER (ASC)

While using a repeater, ASC periodically monitors the strength of signals you
receive directly from the other stations. If the station's signal is strong enough to
allow direct contact without a repeater, the icon blinks.
Press [REV] (1s) to turn the ASC ON.
When the ASC is ON, the icon will appear on the display.
· While direct contact is possible, without the use of a repeater, the icon will begin blinking.
· To exit ASC, press [REV].
Note:
Pressing [PTT] will cause the icon to stop blinking.
ASC does not function if you are using simplex operation.
ASC does not function while scanning.
Activating ASC while using Reverse will switch the Reverse function OFF.
If you recall a Memory channel or the Call channel, and those channels are set up with the
Reverse function switched ON, the ASC will switch OFF.
ASC causes received signals to be momentarily intermitted every 3 seconds.

TONE FREQUENCY ID

This function scans through all tone frequencies to identify the incoming tone
frequency on a received signal. You can use this function to find which tone
frequency is required by your local repeater.
1 Press [TONE] to switch the Tone function ON.
· The icon appears on the display.
2 Press [F], [TONE] (1s) to run the Tone Frequency ID scan.
· The icon blinks and SCAN appears on the display.
· To reverse the scan direction, turn the Tuning control clockwise (upward scan) or
counterclockwise (downward scan).
· To quit the function, press [F] (ESC).
· When the tone frequency is identified, the identified frequency appears on the
display and blinks. Press any key other than the Tuning control while the identified
frequency is blinking, to resume scanning.
3 Press the Tuning control to program the identified frequency in place of the
currently set tone frequency.
· The Tone function will remain ON. You can press [TONE] to switch the Tone function OFF.
· Press [F] (ESC) if you do not want to program the identified frequency.

MEMORY CHANNELS

In Memory channels, you can store frequencies and related data that you often
use. Then you need not reprogram the data every time. You can quickly recall a
programmed channel by simple operation. A total of 1000 Memory channels are
available for bands A and B.

SIMPLEX & REPEATER OR ODD-SPLIT MEMORY CHANNEL?

You can use each memory channel as a simplex & repeater channel or as an odd-
split channel. Store only one frequency to use as a simplex & repeater channel or
two separate frequencies to use as an odd-split channel. Select either application
for each channel depending on the operations you have in mind.
Simplex & repeater channels allow:
· Simplex frequency operation
· Repeater operation with a standard offset (if an offset direction is stored)
Odd-split channels allow:
· Repeater operation with a non-standard offset
The data listed below can be stored in each Memory channel:

Parameter
Simplex & Repeater
Odd-split
Receive frequency
Yes
Yes
Transmit frequency
Yes
Yes
Receive frequency step size
Yes
Yes
Transmit frequency step size
Yes
Yes
Offset direction
Yes
No
Tone ON/OFF
Yes
Yes
Tone frequency
Yes
Yes
CTCSS ON/OFF
Yes
Yes
CTCSS frequency
Yes
Yes
DCS ON/OFF
Yes
Yes
DCS code
Yes
Yes
Reverse ON/OFF
Yes
No
Memory channel lockout
Yes
Yes
Memory channel name
Yes
Yes
Modulation/Demodulation mode
Yes
Yes

 

STORING SIMPLEX AND STANDARD REPEATER FREQUENCIES

1 Press [VFO] to enter VFO mode.
2 Rotate the Tuning control to select your desired frequency.
· Additionally, you can press the microphone [UP]/[DWN] keys to select a frequency.
3 Set up any additional data desired for the frequency.
· Offset direction, Tone ON/OFF, Tone frequency, CTCSS ON/OFF, CTCSS frequency,
DCS ON/OFF, DCS code, etc.
4 Press [F].
· A memory channel number appears.
5 Rotate the Tuning control to select your desired channel number.
· Additionally, you can press the microphone [UP]/[DWN] keys to select a channel.
6 Press [MR] to store the data in the selected Memory channel.
Note: If you store the data in a Memory channel that already has data stored in it, the old data will
be cleared and the new data will be stored.

Call Channel Memory (Simplex)

The Call channel can be used to store any frequency and related data that you
will recall often. You may want to dedicate the Call channel as an emergency
channel within your group.
To store a simplex frequency and related data as the Call channel instead of in
a Memory channel, after step 4 (above), press [CALL].
Note: Storing new data in the Call channel will clear the old data. (The Call channel itself
cannot be cleared, but data can be replaced with new data.)

STORING ODD-SPLIT REPEATER FREQUENCIES

Some repeaters use a receive and transmit frequency pair with a non-standard
offset. To access those repeaters, store two separate frequencies in a memory
channel. You can then operate on those repeaters without changing the offset
frequency you stored in the menu.
1 Set up a simplex channel by following steps 1 to 6 of "STORING SIMPLEX
AND STANDARD REPEATER FREQUENCIES", above.
2 Press [VFO] to enter VFO mode.
3 Rotate the Tuning control to select your desired transmit frequency.
· Additionally, you can press the microphone [UP]/[DWN] keys to select a frequency.
4 Set up any additional data desired for the transmit frequency.
· Tone ON/OFF, Tone frequency, CTCSS ON/OFF, CTCSS frequency, DCS ON/OFF,
DCS code, etc.
5 Press [F].
· A memory channel number appears.
6 Rotate the Tuning control to select your desired channel number.
· Additionally, you can press the microphone [UP]/[DWN] keys to select a channel.
7 Press [PTT], [MR] to store the data in the selected Memory channel.

Call Channel Memory (Odd-Split)

The Call channel can be used to store any frequency and related data that you
will recall often. You may want to dedicate the Call channel as an emergency
channel within your group.
To store an odd-split frequency and related data as the Call channel instead of
in a Memory channel, after step 6 (above), press [PTT], [CALL].
Note: You cannot store the transmit offset status and Reverse status in an odd-split Call channel.

RECALLING A MEMORY CHANNEL

1 Press [MR] to enter Memory Recall mode.
2 Rotate the Tuning control to select your desired Memory channel.
· Additionally, you can press the microphone [UP]/[DWN] keys to select a channel, or
you can enter a channel number using the microphone keypad.

Memory Recall Method

The transceiver Menu also provides you with the option to recall Memory
channels with stored frequencies in your current band, or all Memory channels:
1 Enter Menu mode and access Menu 201 (RECALL).
2 Set the recall method to CURENT (current band) or ALL (all bands).
· CURENT allows you to recall only those memory channels that have stored
frequencies within the current band. ALL allows you to recall all
programmed memory channels.
· When the recalled memory channel is an AM channel, you cannot recall on the B band.

CLEARING A MEMORY CHANNEL

1 Press [MR] to enter Memory Recall mode.
2 Rotate the Tuning control to select your desired Memory channel.
· Additionally, you can press the microphone [UP]/[DWN] keys to select a channel, or
you can enter a channel number using the microphone keypad.
3 Turn the transceiver power OFF.
4 Press [MR] + Power ON.
· A confirmation message appears on the display.
5 Press the Tuning control to clear the Memory channel.
· To exit without clearing the channel, press [F] (ESC).

NAMING A MEMORY CHANNEL

You can name Memory channels using up to 6 alphanumeric characters. When
you recall a named Memory channel, its name appears on the display instead of
the stored frequency. Names can be call signs, repeater names, cities, people, etc.
1 Press [MR] to enter Memory Recall mode.
2 Rotate the Tuning control to select your desired Memory channel.
3 Enter Menu mode and access Menu 200 (M.NAME).
4 Enter your desired name for the channel.
Note: You can overwrite a Memory channel name by performing the steps above. You can also
clear a Memory channel name by clearing the Memory channel.

SWITCHING THE MEMORY NAME / FREQUENCY DISPLAY

After storing memory names, you can switch the display between the memory
name and the stored frequency. This can be useful if you need to confirm the
frequency stored in named Memory channels.
1 Press [MR] to enter Memory Recall mode.
2 Press the Tuning control to toggle between the memory name and the stored frequency.

MEMORY-TO-VFO TRANSFER

Transferring the contents of a Memory channel or the Call channel to the VFO
can be useful if you want to search for other stations or a clear frequency, near
the selected Memory channel or Call channel frequency.
1 Press [MR] or [CALL] to enter Memory Recall mode or select the Call channel.
2 Rotate the Tuning control to select your desired channel. (This step is not
necessary when selecting the Call channel.)
3 Press [F], [VFO].
· The entire contents of the Memory channel or Call channel are copied to the VFO,
and VFO mode is selected after the transfer is complete.
· When copying a transmit frequency from an odd-split Memory or Call channel, you
must first turn the Reverse function ON before pressing [F], [VFO].

CHANNEL DISPLAY FUNCTION

Use this function when you want to use only Memory channels. When this
function is switched ON, the transceiver displays only a Memory channel number
instead of a frequency.
1 Turn the transceiver power OFF.
2 Press [LOW] + Power ON to turn the channel display ON or OFF.
Note:
If no Memory channels have saved data in them, channel display will not function.
If a channel has a stored name, the name will appear on the display in place of the channel number.
When using Channel Display, you cannot reset the transceiver.

While in Channel Display mode, the transceiver keys function as shown below:

Key Name
[KEY]
[F],[KEY]
[KEY] (1s)
While Transmitting
[KEY] + Power ON
Power Key
Power ON/ OFF
Power ON/ OFF
Power ON/ OFF
Power ON/ OFF
X
PM
-
-
-
-
-
VFO
-
-
-
-
-
MR
MR mode
-
Memory Scan
-
-
CALL
Call mode
Store in Call channel
Call Scan
-
-
F
Function mode
Exit Function mode
Key Lock
-
-
TONE
-
-
-
-
-
REV
Reverse ON/OFF
-
-
-
-
LOW
Change output power
Mute
-
Change output power
Change channel display
PF1
Select the Weather channel (K type)
-
-
-
PF2
Change control band
-
-
-
-
Tuning control
Change between the CH number and the channel name
-
Group Scan
-
-
BAND SEL A
A band
-
Change Single/Dual
-
-
BAND SEL B
B band
-
Change Single/Dual
-
-

 

PROGRAMMABLE MEMORY (PM)

Programmable Memory (PM) stores virtually all settings currently set on
the transceiver. This transceiver provides 5 PM channels to store 5 sets of
transceiver configurations. Later, you can quickly recall any one of these
channels, depending on the operations you have in mind or the operating environment.
The following programmable settings cannot be stored:
· Memory name
· Memory channel lockout
· Channel Display mode
· Locked-band/ Cross-band Repeater ON/OFF 1
· Repeater mode 1
· Repeater hold 1
· Repeater ID transmit 1
· Registered repeater ID 1
· Wireless remote control 1
· Answer back 1
· Remote control ID 1
· Key lock
· Power on password 2
· Memory channel/ Call channel/ Program scan memory
· Weather channel 1
· DTMF memory
· EchoLink memory
· PC port speed
· 10 MHz mode 2
· Mic sensitivity 2
· SQC data output logic 2
1 K type only
2 Can be set only by using the MCP-2A software.

APPLICATION EXAMPLES

The following are examples of how you might use Programmable Memory. These
examples may not represent applications useful to you, but you will understand
the flexibility of this function.

Situation:
You share your transceiver with other members in your family or
club. However, each individual has personal preferences for how they like to set
various functions. You have to keep changing many settings each time you use the transceiver.
Solution: Because 5 PM channels are available, up to 5 persons can separately
program the transceiver and store their customized environment. Then each
person can quickly change to his or her favorite settings, simply by recalling a
PM channel. It is too much trouble to change back the settings after somebody
else has reconfigured them. So this application may avoid having a feature-rich
transceiver but never using many useful features.

Situation:
While operating mobile on the way to work every morning, you prefer
a silent transceiver that does not interrupt the morning calm. In addition, you feel
that a bright display is useless in the sunlight. At night when driving home, you
realize the Beep function truly does serve a purpose and you acknowledge it is
nice to see a bright display after dark.
Solution: In 2 PM channels, store the same operating data such as frequency,
offset, tone, etc, and store different settings for the Display brightness and Beep
functions. Then you can quickly recall the best settings for day or night operation.

Situation:
You cannot figure out how to exit the current transceiver mode.
Solution: Simply recall PM channel 1, which contains an exact copy of the
transceiver default environment. You will not lose the contents of any memory
channels.

STORING DATA IN PM CHANNELS

1 Confirm that the following conditions have been satisfied:
· The transceiver is in receive mode.
· Scan is not being used.
· Microphone Control is OFF.
2 Configure the transceiver with your desired settings.
3 Press [F], [PM].
· PM channel numbers 1 to 5 appear and blink at the bottom of the display.
4 Enter a channel number ([1] to [5]) corresponding to your desired PM channel.
· The settings are stored in the PM channel.

RECALLING PM CHANNELS

1 Press [PM].
· PM channel numbers 1 to 5 and OFF appear on the bottom of the display.
2 Enter a channel number ([1] to [5]) corresponding to your desired PM channel.
· The settings stored in the PM channel are recalled.
· The selected channel number appears on the display.
· When selecting [OFF], the PM channels turn off.

AUTO PM CHANNEL STORE

After you recall a PM channel, this function automatically overwrites the current
PM channel with the present operating environment when:
· You recall another PM channel.
· You press [PM].
· You switch the transceiver power OFF.
Follow the steps below to activate the Auto PM storage function.
1 Enter Menu mode and access Menu 521 (AUTO.PM).
2 Set AUTO.PM to ON.

PM CHANNEL RESET

To reset the PM channels to their default settings:
1 Turn the transceiver power OFF.
2 Press [F] + Power ON.
3 Release [F].
4 Rotate the Tuning control and select PM.
5 Press the Tuning control.
· A confirmation message appears on the display.
6 Press the Tuning control again to reset the PM channels.
· Press [TONE] (BACK) to return to the previous display.
· To exit without resetting the PM channels, press [F] (ESC).

SCAN

Scan is a useful feature for hands-off monitoring of your favorite frequencies.
Becoming comfortable with all types of Scan will increase your operating efficiency.
This transceiver provides the following types of scans:
Scan Type
Scan Range
VFO Scan
Scans all frequencies on the current band.
Memory Scan
Scans all frequencies stored in the Memory channels.
Group Scan
Scans the frequencies in the Memory channels which belong to the group you have specified.
Program Scan
Scans all frequencies within the programmed range, on the current band.
MHz Scan
Scans all frequencies within a 1 MHz range from the originating frequency.
Call Scan
Scans the Call channel as well as the currently selected VFO frequency or Memory channel.
Note:
Adjust the squelch level before using Scan. Selecting a squelch level too low could cause
Scan to stop immediately.
While using CTCSS or DCS, Scan stops for any signal received; however, you will hear audio
only when the signal contains the same CTCSS tone or DCS code that you selected.
When using S-meter Squelch, Scan stops when the received signal strength matches or
exceeds the S-meter setting. Scan resumes 2 seconds after the signal level drops below the
S-meter setting.
Pressing and holding [PTT] causes Scan to temporarily stop if it is functioning on a non TX band.
Starting Scan switches the Automatic Simplex Checker OFF.

SELECTING A SCAN RESUME METHOD

The transceiver stops scanning at a frequency or Memory channel on which a
signal is detected. It then continues scanning according to which resume mode
you have selected. You can choose one of the following modes. The default is
Time-operated mode.
· Time-Operated mode
The transceiver remains on a busy frequency or Memory channel for
approximately 5 seconds, and then continues to scan even if the signal is still present.
· Carrier-Operated mode
The transceiver remains on a busy frequency or Memory channel until the
signal drops out. There is a 2 second delay between signal drop-out and scan resumption.
· Seek mode
The transceiver remains on a busy frequency or Memory channel even after
the signal drops out and does not automatically resume scanning.
Note: To temporarily stop scanning and monitor weak signals, press the microphone PF key
assigned to the Monitor function. Press the PF key again to resume scanning.
1 Enter Menu mode and access Menu 514 (SC.RESM).
2 Set the Scan Resume mode to TO (Time-Operated), CO (Carrier-Operated) or SEEK.

VFO SCAN

VFO Scan monitors all frequencies tunable on the band, using the current frequency step size.
1 Select your desired band.
2 Press [VFO] (1s).
· Scan starts at the current frequency.
· The 1 MHz decimal blinks while scanning is in progress.
· To reverse the scan direction, turn the Tuning control clockwise (upward scan) or
counterclockwise (downward scan). You can also press microphone [UP]/ [DWN].
3 To quit VFO Scan, press [VFO] again.

MEMORY SCAN

Use Memory Scan to monitor all Memory channels programmed with frequency data.
1 Select your desired band.
2 Press [MR] (1s).
· Scan starts at the current frequency.
· The 1 MHz decimal blinks while scanning is in progress.
· To reverse the scan direction, turn the Tuning control clockwise (upward scan) or
counterclockwise (downward scan). You can also press microphone [UP]/ [DWN].
3 To quit Memory Scan, press [MR] again.
Note:
At least 2 Memory channels must contain data and must not be locked out of scan.
The L0/U0 to L9/U9 Memory channels will not be scanned.
You can also start Memory Scan when in Channel Display mode. While Scan is paused on a
channel, the channel number blinks.

Locking Out a Memory Channel

You can select Memory channels that you prefer not to monitor while scanning.
1 Press [MR], then rotate the Tuning control to select your desired channel.
2 Enter Menu mode and access Menu 202 (L.OUT).
3 Set the lockout to ON to lock the channel out of the scanning sequence.
· To cancel lockout, set the lockout to OFF.
· The icon appears on the display for a channel that has been locked out.
Note: The L0/U0 to L9/U9 Memory channels cannot be locked out.

GROUP SCAN

For the purpose of Group Scan, the 1000 Memory channels are divided into 10
groups, with each group containing 100 channels. Group Scan monitors only the
100 channels which belong to the specific group you are scanning. The channels
are grouped as follows:

Memory Group
Channel Range
0
0 ~ 99
1
100 ~ 199
2
200 ~ 299
3
300 ~ 399
4
400 ~ 499
5
500 ~ 599
6
600 ~ 699
7
700 ~ 799
8
800 ~ 899
9
900 ~ 999


1 Press [MR], then rotate the Tuning control to select a channel in your desired group.
2 Press the Tuning control (1s).
· Scan starts at the current channel.
· The 1 MHz decimal blinks while scanning is in progress.
· To reverse the scan direction, turn the Tuning control clockwise (upward scan) or
counterclockwise (downward scan). You can also press microphone [UP]/ [DWN].
3 To quit Group Scan, press the Tuning control again.
Note:
At least 2 Memory channels in the selected group must contain data and must not be locked
out of scan.
You can also start Memory Scan when in Channel Display mode. While Scan is paused on a
channel, the channel number blinks.

Memory Group Link

Memory Group Link provides you with the ability to link 2 or more Memory
channel groups together to act as a single group when scanning. You can link
up to 6 separate groups together, or even add multiple instances of the same
group to the group link, to ensure that one group is scanned more often than
the other groups.
1 Enter Menu mode and access Menu 203 (GR.LINK).
2 Press the Tuning control.
· The cursor will begin blinking.
3 Rotate the Tuning control to select a group to link.
4 Press the Tuning control to set the group and move the cursor to the right.
· Press [REV] ( ) to move the cursor back or [LOW] ( ) to move the cursor to the right.
5 Repeat steps 3 and 4 to link additional groups together.
6 When you have entered your desired groups, press [LOW] ( ) to move the
cursor to the right, then press the Tuning control to complete the entry and
exit Menu mode.
· If you have entered the maximum of 6 groups, simply press the Tuning control to
complete the entry and exit Menu mode.

PROGRAM SCAN

Program Scan is identical to VFO Scan except that you select a frequency range for the scan.
Setting Scan Limits
You can store up to 10 scan ranges in Memory channels L0/U0 to L9/U9.
1 Select your desired band.
2 Press [VFO].
3 Rotate the Tuning control to select your desired frequency for the lower limit.
4 Press [F].
· A memory channel number appears and blinks.
5 Rotate the Tuning control to select a channel from L0 to L9.
6 Press [MR] to set the channel number.
· The lower limit is stored in the channel.
7 Rotate the Tuning control to select your desired frequency for the lower limit.
8 Press [F].
9 Rotate the Tuning control to select a matching channel number from U0 to U9.
· For example, if you select channel L3 in step 5, select channel U3 here.
10 Press [MR] to set the channel number.
· The upper limit is stored in the channel.
· To confirm the stored scan limits, press [MR], then select the L and U channels.
Note:
The lower limit must be lower in frequency than the upper limit.
The lower and upper frequency step sizes must be equal.
The lower and upper limits must be selected on the same band.

Using Program Scan

1 Select your desired band.
2 Press [VFO].
3 Rotate the Tuning control to select a frequency within your desired scan range.
4 Press [VFO] (1s).
· Scan starts at the current frequency.
· The 1 MHz decimal blinks while scanning is in progress.
· To reverse the scan direction, turn the Tuning control clockwise (upward scan)
or counterclockwise (downward scan). You can also press microphone [UP]/ [DWN].
5 To quit Program Scan, press [VFO] again.
Note:
If the step size differs between the lower limit and upper limit, VFO scan will begin instead
of Program Scan.
u If the current VFO frequency is within more than one Program Scan range, the range
stored in the smallest channel number is used.

MHz SCAN

MHz Scan monitors a 1 MHz segment of the band, using the current frequency
step size. The current 1 MHz digit determines the limits of the scan. For
example, if the current frequency is 145.400 MHz, then the scan range would be
from 145.000 MHz to 145.995 MHz (the exact upper limit depends on the current
frequency step size).
1 Select your desired band.
2 Press [VFO].
3 Rotate the Tuning control to select a frequency within your desired 1 MHz range.
4 Press and hold the Tuning control for 1 second to start scanning.
· Scan starts at the current frequency.
· The 1 MHz decimal blinks while scanning is in progress.
· To reverse the scan direction, turn the Tuning control clockwise (upward scan) or
counterclockwise (downward scan). You can also press microphone [UP]/ [DWN].
5 To quit MHz Scan, press the Tuning control again.

CALL SCAN

Use Call Scan to monitor both the Call channel and either the currently selected
VFO frequency or the currently selected Memory channel.
1 Select your desired VFO frequency or Memory channel.
2 Press [CALL] (1s) to start Call Scan.
· The 1 MHz decimal blinks while scanning is in progress.
· When scanning a Memory channel, the Call channel on the same band as the
selected Memory channel is used for scan.
3 To quit Call Scan, press [CALL] again.
Note: The Memory channel selected is scanned even if it has been locked out of scan.

CONTINUOUS TONE CODED SQUELCH SYSTEM (CTCSS)

You may sometimes want to hear calls only from specific persons. The
Continuous Tone Coded Squelch System (CTCSS) allows you to ignore (not
hear) unwanted calls from other persons who are using the same frequency. To
do so, select the same CTCSS tone as selected by the other persons in your
group. A CTCSS tone is sub audible and is selectable from among 42 tone
frequencies.
Note: CTCSS does not cause your conversation to be private. It only relieves you from listening
to unwanted conversations.

USING CTCSS

1 Select your desired band.
2 Press [TONE] 2 times to activate the CTCSS function.
· The icon appears on the display when the CTCSS function is ON.
· Each press of [TONE] changes the selection as follows:
Tone (T) -> CTCSS (CT) -> DCS (DCS) -> Off (no display).
3 Press [F], [TONE].
· The current CTCSS frequency appears on the display and blinks.
4 Rotate the Tuning control to select your desired CTCSS frequency.
· Refer to the table below for the available frequencies.
· To exit the CTCSS frequency selection, press [F] (ESC).
5 Press any key other than the Tuning control and [F] (ESC) to complete the setting.
6 When you are called: The transceiver squelch opens only when the selected
CTCSS tone is received.
When you make a call: Press and hold [PTT], then speak into the microphone.
· To cancel CTCSS, press [TONE] until CT no longer appears on the display.
You can also select a CTCSS frequency by using the microphone:
1 Select your desired band.
2 Press [TONE] 2 times to activate the CTCSS function.
· The icon appears on the display when the CTCSS function is ON.
· Each press of [TONE] changes the selection as follows:
Tone (T) -> CTCSS (CT) -> DCS (DCS) -> Off (no display).
3 Press [F], [TONE].
· The current CTCSS frequency appears on the display and blinks.
4 Press the key programmed as [ENTER].
5 Enter a frequency reference number (01 ~ 42) using the microphone keypad.
· Refer to the table below for frequencies and their reference numbers.
6 Press [ENTER] again to complete the setting.

Tone Number
Frequency (Hz)
01
67.0
02
69.3
03
71.9
04
74.4
05
77.0
06
79.7
07
82.5
08
85.4
09
88.5
10
91.5
11
94.8
12
97.4
13
100.0
14
103.5
15
107.2
16
110.9
17
114.8
18
118.8
19
123.0
20
127.3
21
131.8
22
136.5
23
141.3
24
146.2
25
151.4
26
156.7
27
162.2
28
167.9
29
173.8
30
179.9
31
186.2
32
192.8
33
203.5
34
206.5
35
210.7
36
218.1
37
225.7
38
229.1
39
233.6
40
241.8
41
250.3
42
254.1

 

CTCSS FREQUENCY ID

This function scans through all CTCSS frequencies to identify the incoming
CTCSS frequency on a received signal. You may find this useful when you
cannot recall the CTCSS frequency that the other persons in your group are using.
1 Press [TONE] 2 times to activate the CTCSS function.
· The icon appears on the display when the CTCSS function is ON.
· Each press of [TONE] changes the selection as follows:
Tone (T) -> CTCSS (CT) -> DCS (DCS) -> Off (no display).
2 Press [F], [TONE] (1s).
· The icon blinks and "SCAN" appears on the display.
· Scan starts when a signal is received.
· To reverse the scan direction, turn the Tuning control clockwise (upward scan) or
counterclockwise (downward scan). You can also press microphone [UP]/ [DWN].
· To quit the scan, press [F] (ESC).
· When a CTCSS frequency is identified, the identified frequency appears on the display and blinks.
3 Press the Tuning control to program the identified frequency in place of the
currently set CTCSS frequency.
· The CTCSS function will remain ON. To cancel CTCSS, press [TONE] until CT no
longer appears on the display.
· Press [F] (ESC) if you do not want to program the identified frequency.
· Rotate the Tuning control while an identified frequency is blinking, to resume scanning.

DIGITAL CODED SQUELCH (DCS)

Digital Code Squelch (DCS) is another application which allows you to ignore (not
hear) unwanted calls. It functions the same way as CTCSS. The only differences
are the encode/ decode method and the number of selectable codes. For DCS,
you can select from 104 different codes.

USING DCS

1 Select your desired band.
2 Press [TONE] 3 times to activate the DCS function.
· The (graphic symbol) icon appears on the display when the DCS function is ON.
· Each press of [TONE] changes the selection as follows:
Tone (T) -> CTCSS (CT) -> DCS (DCS) -> Off (no display).
3 Press [F], [TONE].
· The current DCS code appears on the display and blinks.
4 Rotate the Tuning control to select your desired DCS code.
· Refer to the table below for the available codes.
· To exit the DCS code selection, press [F] (ESC).
5 Press any key other than the Tuning control and [F] (ESC) to complete the setting.
6 When you are called: The transceiver squelch opens only when the selected
DCS code is received.
When you make a call: Press and hold [PTT], then speak into the microphone.
· To cancel DCS, press [TONE] until DCS no longer appears on the display.
You can also select a DCS code by using the microphone:
1 Select your desired band.
2 Press [TONE] 3 times to activate the DCS function.
· The (graphic symbol) icon appears on the display when the DCS function is ON.
· Each press of [TONE] changes the selection as follows:
Tone (T) -> CTCSS (CT) -> DCS (DCS) -> Off (no display).
3 Press [F], [TONE].
· The current DCS code appears on the display and blinks.
4 Press the key programmed as [ENTER].
5 Enter your desired DCS code using the microphone keypad.
· Refer to the table below for DCS codes.
6 Press [ENTER] again to complete the setting.

DCS Code
023
025
026
031
032
036
043
047
051
053
054
065
071
072
073
074
114
115
116
122
125
131
132
134
143
145
152
155
156
162
165
172
174
205
212
223
225
226
243
244
245
246
251
252
255
261
263
265
266
271
274
306
311
315
325
331
332
343
346
351
356
364
365
371
411
412
413
423
431
432
445
446
452
454
455
462
624
465
466
503
506
516
523
565
532
546
565
606
612
624
627
631
632
654
662
664
703
712
723
731
732
734
743
754

 

DCS CODE ID

This function scans through all DCS codes to identify the incoming DCS code on
a received signal. You may find it useful when you cannot recall the DCS code
that the other persons in your group are using.
1 Press [TONE] 3 times to activate the DCS function.
· The (graphic symbol) icon appears on the display when the DCS function is ON.
· Each press of [TONE] changes the selection as follows:
Tone (T) -> CTCSS (CT) -> DCS (DCS) -> Off (no display).
2 Press [F], [TONE] (1s).
· The (graphic symbol) icon blinks and "SCAN" appears on the display.
· Scan starts when a signal is received.
· To reverse the scan direction, turn the Tuning control clockwise (upward scan) or
counterclockwise (downward scan). You can also press microphone [UP]/ [DWN].
· To quit the scan, press [F] (ESC).
· When a DCS code is identified, the identified code appears on the display and blinks.
3 Press the Tuning control to program the identified code in place of the
currently set DCS code.
· The DCS function will remain ON. To cancel DCS, press [TONE] until DCS no
longer appears on the display.
· Press [F] (ESC) if you do not want to program the identified code.
· Rotate the Tuning control while an identified code is blinking, to resume scanning.

DUAL TONE MULTI-FREQUENCY (DTMF)

The keys on the microphone keypad function as DTMF keys; the 12 keys found
on a push-button telephone plus 4 additional keys (A, B, C, D). This transceiver
provides 10 dedicated memory channels. You can store a DTMF code with up to 16 digits.
Some repeaters in the U.S.A. and Canada offer a service called Autopatch. You
can access the public telephone network via such a repeater by sending DTMF
tones. For further information, consult your local repeater reference.

MANUAL DIALING

Manual Dialing requires only two steps to send DTMF tones.
1 Press and hold the microphone [PTT].
2 Press the keys in sequence on the keypad to send DTMF tones.
· The corresponding DTMF tones are transmitted.
· If the DTMF Hold function is activated, you need not hold down [PTT] while pressing
keys. After transmitting the first tone (by pressing [PTT] and the first key), pressing
additional keys will keep the transceiver in transmit mode for 2 seconds.

Frequency (Hz)
1209
1336
1447
1633
697
[1]
[2]
[3]
[A]
770
[4]
[5]
[6]
[B]
852
[7]
[8]
[9]
[C]
941
[ ]
[0]
[#]
[D]

DTMF Hold

Activate this function to remain in transmit mode, after beginning to press keys
when making a call.
1 Enter Menu mode and access Menu 300 (DT.HOLD).
2 Set DTMF Hold to ON to continue transmitting when pressing keys.
· Set this menu to OFF to stop the 2 second continuous transmission.

AUTOMATIC DIALER

There are 10 dedicated DTMF Memory channels available to store DTMF codes.
You can store up to 16 digits in each channel.

Storing a DTMF Code in Memory

1 Enter Menu mode and access Menu 301 (DT.MEM).
2 Rotate the Tuning control to select a channel number.
3 Press the Tuning control to set the selected channel number.
· The name entry display appears.
4 Enter a name for the channel, the press the Tuning control to set it.
· The code entry display appears.
5 Enter a DTMF code for the channel, then press the Tuning control to set it.

Transmitting Stored DTMF Codes

1 Press and hold the microphone [PTT].
2 While transmitting, press the Tuning control.
· The last called DTMF Memory channel name and number appear on the display.
If no name has been saved for the channel, the DTMF code appears.
3 While still transmitting, rotate the Tuning control to select your desired
DTMF Memory channel, then press the Tuning control to set the channel.
· Additionally, you can press a DTMF key corresponding to your desired channel
([0] ~ [9]) to select the channel and begin transmission.
· The stored DTMF code scrolls across the display and is transmitted.
· The code will be transmitted even if you release [PTT] before the entire code has
scrolled across the display.
· If no DTMF code is stored in the selected channel, the frequency display is restored.

Selecting a Transmit Speed

Some repeaters may not respond correctly if a DTMF code is transmitted at
fast speed. If this happens, change the DTMF code transmission speed from
FAST (default) to SLOW.
1 Enter Menu mode and access Menu 302 (DT.SPD).
2 Set the speed to FAST or SLOW.

Selecting a Pause Duration

You can change the pause duration stored in DTMF Memory channels; the
default is 500 mSec
1 Enter Menu mode and access Menu 303 (DT.PAUS).
2 Select a speed (in sec) from the available list: 100/ 250/ 500/ 750/ 1000/ 1500/ 2000.

DTMF KEY LOCK

This function will lock the DTMF transmission keys so that they will not transmit if
they are accidentally pressed. To lock the DTMF keys, turn this function ON.
1 Enter Menu mode and access Menu 304 (DT.LOCK).
2 Set the key lock to ON or OFF.

EchoLink®

What is EchoLink?

EchoLink allows you to communicate with other amateur radio stations over the
internet, using VoIP (voice-over-IP) technology. The EchoLink software program
allows worldwide connections to be made between stations, or from computer to
station, greatly enhancing your communications capabilities.
To use EchoLink, you must register using your call sign on their website and
download the EchoLink software program (free of charge). Refer to the website
for PC hardware and other requirements.
Official EchoLink Website: http://www.echolink.org
Note: EchoLink is a registered trademark of Synergenics, LLC.

STORING EchoLink MEMORY

There are 10 dedicated EchoLink DTMF Memory channels available to store
DTMF codes. You can store up to 8 digits in each channel.
1 Enter Menu mode and access Menu 204 (ELK.MEM).
2 Rotate the Tuning control to select an EchoLink channel number from EL0 ~ EL9.
3 Press the Tuning control to set the selected channel number.
· The name entry display appears.
4 Enter the name for the channel, then press the Tuning control to set it.
· The code entry display appears.
5 Enter a DTMF code for the channel, then press the Tuning control to set it.

Transmitting EchoLink Memory

1 Select the band and frequency of the node to which you want to connect.
2 Press and hold the microphone [PTT].
3 While transmitting, press the Tuning control.
· The last called EchoLink DTMF Memory channel name and number appears on the display.
4 While still transmitting, rotate the Tuning control to select your desired
EchoLink Memory channel, then press the Tuning control to set the channel.
· The stored code scrolls across the display and is transmitted.
· The code will be transmitted even if you release [PTT] before the entire code has
scrolled across the display.
· When only a name has been stored, the DTMF code for that name appears on
the display. The Call Sign code is automatically proceeded with a "C" and ends
with a "#". DTMF values are listed in the following table:

1
2
3
4
5
6
7
8
9
0
0
1
2
3
4
5
6
7
8
9
0
1
Q
A
D
G
J
M
P
T
W
2
Z
B
E
H
K
N
R
U
X
3
 
C
F
I
L
O
S
V
Y

So, for example, if the Call Sign being transmitted was JA1YKX, the display
would read: C 51 21 10 93 52 92 #
However, if characters other than letters or numbers are used (such as a hyphen
or a space), only the DTMF code for characters before that non-regular character
are displayed. All subsequent characters will not appear on the display.
· If no data is stored in the selected channel, the frequency display is restored.

Selecting a Transmit Speed

Some repeaters may not respond correctly if a code is transmitted at fast
speed. If this happens, change the EchoLink transmission speed from FAST
(default) to SLOW.
1 Enter Menu mode and access Menu 205 (ELK.SPD).
2 Set the speed to FAST or SLOW.

SETTING UP EchoLink SYSOP MODE

When connected to a PC, you can set whether or not to use the RTS and CTS
terminals for hard flow control, or the SQC and PKS terminals for EchoLink. The
action band is the data band (Menu 517(DAT.BND)).
1 Turn the transceiver power OFF.
2 Press [PF2] + Power ON to turn EchoLink Sysop Mode ON.
· The (graphic symbol) icon appears on the display when EchoLink Sysop mode is ON.
· To turn EchoLink Sysop Mode OFF, press [PF2] + Power ON again.

EchoLink Sysop Mode ON
TM-V71
 
PC
TxD
->
RxD
RxD
<->
TxD
SQC
->
CTS
PKS
<->
RTS
GND
<->
GND

EchoLink Sysop Mode OFF
TM-V71
 
PC
TxD
->
RxD
RxD
<->
TxD
RTS
->
CTS
CTS
<->
RTS
GND
<->
GND


Note:
When in EchoLink Sysop mode, you cannot change to Repeater mode or Remote Control
mode. Additionally, you cannot use the MCP-2A (memory control program) software.
We recommend you set Menu 520's SQC output setting to SQL when using EchoLink Sysop mode.

AUXILIARY FUNCTIONS

POWER-ON MESSAGE

Each time you switch the transceiver ON, "HELLO" (default) appears on the
display for approximately 2 seconds. You can program your favorite message in
place of the default message.
1 Enter Menu mode and access Menu 500 (P.ON.MSG).
2 Enter your desired message.
· Press [PF1] (CLR) to clear the entire message, if necessary.

DISPLAY BRIGHTNESS

You can manually change the display illumination to suit the lighting conditions
where you are operating.
1 Enter Menu mode and access Menu 501 (BRIGHT).
2 Set your desired brightness level from 1 to 8, or OFF.

Auto Display Brightness

When Auto Brightness is activated, the display will light up every time a key is pressed.
1 Enter Menu mode and access Menu 502 (AUTO.BR).
2 Set the Auto Brightness function to ON or OFF.

Backlight Color

You can manually change the display illumination to suit the lighting conditions where you are operating.
1 Enter Menu mode and access Menu 503 (COLOR).
2 Set the backlight color to AMBER or GREEN.

KEY LOCK

The Key Lock function ensures that your transceiver settings will remain
unchanged if you accidentally press a key. When activated, the following
functions can still be used:
· [Power Key ]
· [PTT]
To turn Key Lock ON or OFF, press [F] (1s).
· When Key Lock is activated, the icon will appear on the display.

Microphone Key Lock

The Microphone Key Lock function will lock the microphone PF (Programmable
Function) keys.
1 Enter Menu mode and access Menu 513 (MIC.LCK).
2 Turn the Microphone Key Lock function ON or OFF.

KEY BEEP

You can turn the transceiver beep function ON or OFF as desired.
1 Enter Menu mode and access Menu 000 (BEEP).
2 Turn the beep function ON or OFF.
· Even with the beep function turned OFF, the transceiver will emit a beep tone under
the following conditions:
1) When Auto Power Off is activated, the transceiver will beep 1 minute before the power turns off.
2) After transmitting for the maximum time duration according to the Time-out Timer,
the transceiver will beep

Beep Volume

Each time you press a key, the beep tone will sound. If you have left the beep
function turned ON, you may wish to adjust the volume level of the beep.
1 Enter Menu mode and access Menu 001 (BP.VOL).
2 Set the beep volume to a level from 1 to 7.
· The default is level 5.

PROGRAMMABLE VFO

If you always check frequencies within a certain range, you can set upper and
lower limits for frequencies that are selectable. For example, if you select 144
MHz for the lower limit and 145 MHz for the upper limit, the tunable range will be
from 145.000 MHz to 146.995 MHz.
1 Press the left or right [BAND SEL] to set band A or B as the operating band,
then press [VFO].
2 Enter Menu mode and access Menu 100 (PRG.VFO).
(Example: E type)
3 Press the Tuning control.
· The lower frequency limit blinks.
4 Rotate the Tuning control to select your desired lower frequency limit, then
press the Tuning control to set the selected value.
· The upper frequency limit blinks.
· When setting the limit for the 1200 MHz band, the 1 MHz digit appears on the
7-segment display to the right of the main display.
5 Rotate the Tuning control to select your desired upper frequency limit, then
press the Tuning control to set the selected value.
6 Press [CALL] (ESC) to exit Menu mode.
Note: You cannot program the 100 kHz and subsequent digits. The exact 100 kHz and
subsequent digits of the upper limit depend on the frequency step size you are using.

CHANGING THE FREQUENCY STEP SIZE

Choosing the correct frequency step size is essential in selecting your exact
frequency. The default step size on the 144 MHz band is 5 kHz (K type) or
12.5 kHz (E, M4 types). The default on the 430/440 MHz band is 25 kHz. For K
type models, the default on the 118, 220, or 300 MHz band is 12.5 kHz and the
default on the 1200 MHz band is 25 kHz.
1 Press the left or right [BAND SEL] to select band A or B, then press [VFO].
2 Enter Menu mode and access Menu 101 (STEP).
3 Set the step size to 5.0*, 6.25*, or 8.33 kHz (118 MHz band only) or to 10.0,
12.5, 15.0*, 20.0, 25.0, 30.0, 50.0, or 100.0 kHz.
* These step sizes are not available for the 1200 MHz band.
Note: Changing between step sizes may correct the displayed frequency. For example, if
144.995 MHz is displayed with a 5 kHz step size selected, changing to a 12.5 kHz step size
corrects the displayed frequency to 144.9875 MHz.

PROGRAMMABLE FUNCTION KEYS

Transceiver Front Panel

There are 2 PF (Programmable Function) keys on the transceiver front panel:
PF1 and PF2. You can assign your own desired functions to these 2 keys.
1 Enter Menu mode and access Menu 507 (PF1) and/or Menu 508 (PF2).
2 Set your desired function for the key. Programmable functions available
are: WX CH (Weather Channel)/ FR.BAND (Frequency bands)/ CTRL
(Control)/ MONI (Monitor)/ VGS (Voice recorder)/ VOICE (Voice
announcement)/ GRP.UP (Memory group up)/ MENU (Menu mode)/ MUTE
(Speaker Mute)/ SHIFT (Shift)/ DUAL (Dual Mode)/ M>V (Memory to VFO
Copy)/ 1750 (1750 Hz Tone).

Microphone Keys

There are 4 microphone PF (Programmable Function) keys: [PF] (PF1), [MR]
(PF2), [VFO] (PF3) and [CALL] (PF4). You can assign your own desired
functions to these 4 keys.
1 Enter Menu mode and access Menu 509 (MIC.PF1) and/or Menu 510
(MIC. PF2) and/or Menu 511 (MIC. PF3) and/or Menu 512 (MIC. PF4).
2 Set your desired function for the key. Programmable functions available
are: WX CH (Weather Channel)/ FR.BAND (Frequency bands)/ CTRL
(Control)/ MONI (Monitor)/ VGS (Voice recorder)/ VOICE (Voice
announcement)/ GRP.UP (Memory group up)/ MENU (Menu mode)/ MUTE
(Speaker Mute)/ SHIFT (Shift)/ DUAL (Dual Mode)/ M>V (Memory to VFO
Copy)/ VFO/ MR/ CALL/ MHz/ TONE/ REV (Reverse)/ LOW/ LOCK/ A/B
(Band Select A/ Band Select B)/ ENTER/ 1750 (1750 Hz Tone).

FREQUENCY DIRECT ENTRY

If the desired operating frequency is far from the current frequency, using the
microphone keypad is the quickest way to change the frequency. One of the
microphone PF keys must first be programmed as ENTER,
1 Press the left or right [BAND SEL] to select band A or B, then press [VFO] or [CALL].
2 Press the key programmed as [ENTER].
· The Direct Frequency Entry display appears.
3 Press the microphone keys ([0] ~ [9]) to enter your desired frequency.
4 To set the entered frequency, press [ENTER] or [VFO].
· Pressing [ENTER] before entering all of the digits will set the remaining digits to 0.
· Pressing [VFO] before entering all of the digits will leave the remaining digits at their
previous values.
· Entering all digits for a frequency will automatically set the frequency without
pressing [ENTER] or [VFO].
· If you need to only change the MHz digit, press the Tuning control, then enter the new value.

AUTOMATIC POWER OFF (APO)

Automatic Power Off is a background function that monitors whether or not any
operations have been performed (keys pressed, Tuning control turned, etc.), and
turns the transceiver power OFF if it has not been in use.
1 Enter Menu mode and access Menu 516 (APO).
2 Set the APO time limit to 30, 60, 90, 120, 180 minutes, or OFF.
· After the time limit passes with no operations (default is 180 minutes), APO turns
the transceiver power OFF. However, 1 minute before the power turns OFF, "APO"
appears on the display and blinks, and a warning tone sounds.
Note: If any settings are changed during while APO is ON, the timer resets. When you stop
changing the settings, the timer begins counting again from 0.

S-METER SQUELCH

S-meter Squelch causes the squelch to open only when a signal with the same or
greater strength than the S-meter setting is received. This function relieves you
from constantly resetting the squelch when receiving weak stations that you have no interest in.
1 Enter Menu mode and access Menu 105 (S.SQL).
2 Set the S-Meter squelch to ON or OFF.
3 To select the desired S-meter setting, rotate the left (band A) or right (band B)
SQL control depending on which band you have selected.
· The squelch will open only at the level you have selected (for example, level 9).

Squelch hang Time

When using S-meter Squelch, you may want to adjust the time interval
between when the received signals drop and when the squelch closes.
1 Enter Menu mode and access Menu 106 (S.SQ.HNG).
2 Set the hang time to 125 or 500 ms, or OFF.

ADVANCED INTERCEPT POINT (AIP)

The VHF/UHF band is often crowded in urban areas. AIP helps eliminate
interference and reduce audio distortion caused by intermodulation. You can use
this function only while operating on the VHF/UHF band.
1 Enter Menu mode and access Menu 103 (VHF.AIP) and/or Menu 104
(UHF.AIP).
2 Set the AIP to ON or OFF.

SWITCHING FM/AM MODE

This transceiver is also capable of receiving (not transmitting) in AM on band A.
The default mode on the 118 MHz band is AM while the default on the 144, 220,
300, or 430/440 MHz band is FM.
1 Enter Menu mode and access Menu 102 (MODLAT).
2 Set the mode to AM, FM, or NFM.
Note: You cannot switch between FM and AM to receive on band B.

BEAT SHIFT

Since the transceiver uses a microprocessor to control various transceiver
functions, the CPU clock oscillator's harmonics or image may appear on some
spots of the reception frequencies. In this case, we recommend you turn the Beat Shift function ON.
1 Enter Menu mode and access Menu 108 (B.SHIFT).
2 Set the Beat Shift to ON or OFF.

SPEAKER MUTE

While receiving or transmitting on the TX band, you may not want to hear audio
received on the other band. Use this function to mute the speaker allocated to
that band (not the TX band).
While receiving, press [F], [LOW] to switch the mute function ON or OFF.
· The (graphic symbol) icon appears on the display when the function is ON.

Mute hang Time

When using Speaker Mute, you may want to adjust the time interval between
when you receive a signal and when the speaker is muted.
1 Enter Menu mode and access Menu 107 (MUT.HNG).
2 Set the hang time to 125, 250, 500, 750, or 1000 ms.

SELECTING AN OUTPUT POWER

It is a good idea to select lower transmit power if communications is still reliable.
This lowers the risk of interfering with others on the band. When operating from
battery power, you will enjoy more operating time before a recharge is necessary.
Press [LOW] to select high (H) (K, E types only), medium (M), or low (L) power. .
· You can program different power settings for bands A and B.
Note: When the transceiver overheats because of ambient high temperature or
continuous transmission, the protective circuit may function to lower transmit
output power.

TIME-OUT TIMER (TOT)

It is sometimes necessary or desirable to restrict a single transmission to a
specific maximum time. You may use this function to prevent repeater time-outs
when accessing repeaters, or to conserve battery power.
When TOT times out (default is 10 minutes), the transceiver generates beeps and
automatically returns to receive mode. To resume transmitting, release and then
press the microphone [PTT] again.
1 Enter Menu mode and access Menu 109 (TOT).
2 Set the timer to 3, 5, or 10 minutes.

EXTERNAL SPEAKER CONFIGURATION

This transceiver has two speaker jacks for external speakers, as well as an
internal speaker. You can enjoy a variety of speaker configurations by using
one or two external speakers. Received signals on bands A and B are output
depending on how you want the internal and/or external speakers to function.
1 Enter Menu mode and access Menu 002 (EXT.SP).
2 Set the speaker mode to MODE 1 or MODE 2.
· Refer to the table below for configurations based on the mode selected.

Mode
Speaker Setup
Internal Speaker
External SP1
External SP2
MODE 1
None
A & B
-
-
MODE 1
SP1 only
x
A & B
-
MODE 1
SP2 only
A
-
B
MODE 1
SP1 & SP2
x
A
B
MODE 2
None
A & B
-
-
MODE 2
SP1 only
x
A & B
-
MODE 2
SP2 only
B
-
A
MODE 2
SP1 & SP2
x
B
A

 

MASKING A BAND

If you have no plans to use band A or B, you can hide the frequency display on
the unused band. This saves power consumption and makes it simpler to read
the information you need.
1 Turn the transceiver power OFF.
2 Press the left or right [BAND SEL] + Power ON.
· The band mask display appears.
3 Rotate the Tuning control to select the band you want to hide (or return to normal).
4 Press the Tuning control to set the selected band.
5 Rotate the Tuning control to set the band to select USE or MASK.
· USE allows you to see and use the band as normal. MASK hides the band on the display.
6 Press the Tuning control to set the selection.
7 Press the [CALL] (ESC) to exit.
Note: You cannot operate the masked band nor use it to receive or transmit.

DISPLAY PARTITION BAR

The partition bar that appears between bands A and B can be removed if desired.
1 Enter Menu mode and access Menu 527 (DP.BAR).
2 Set the partition bar display to ON or OFF.

WEATHER ALERT (K TYPE MODELS ONLY)

The Weather Alert is available only in the USA and Canada. When activated,
this function will check for a received NOAA 1050 Hz tone. When the tone is
received, the weather alert tone will sound.
1 Enter Menu mode and access Menu 110 (WX.ALT).
2 Set the Weather Alert to ON or OFF.
· When activated, the icon appears on the display.
· When a signal is being received, the icon blinks.

Weather Channel

Whether or not the Weather Alert is activated, you can still access the weather
channels. The Weather Alert simply notifies you of activity on the weather channels.
1 Press the key programmed with the WX function.
2 Rotate the Tuning control to select your desired channel.

Channel No.
Frequency (MHz)
Memory Name
Location
A1
162.550
WX 1
NOAA/ Canada
A2
162.400
WX 2
NOAA/ Canada
A3
162.475
WX 3
NOAA/ Canada
A4
162.425
WX 4
NOAA
A5
162.450
WX 5
NOAA
A6
162.500
WX 6
NOAA
A7
162.525
WX 7
NOAA
A8
161.650
WX 8
Canada
A9
161.775
WX 9
Canada
A10
163.275
WX 10
-

 

POWER ON PASSWORD

If power on password is activated, you cannot operate the transceiver without first
entering your password, after turning the transceiver power ON. Your password
can be changed using the MCP-2A software, and can contain up to 6 digits.
1 Enter Menu mode and access Menu 998 (PASSWD).
2 Set the power on password to ON or OFF.
· When set to ON, "PASSWD" appears on the display.
3 Enter your password.
[F]: 1
[TONE]: 2
[REV]: 3
[LOW]: 4
[PF1]: 5
4 After entering up to 6 digits, press the Tuning control to set the password.
Note: Even with Menu 998 turned ON, the power on password function will not be activated unless
you first program a password using the MCP-2A software.

VGS-1 OPTIONAL VOICE GUIDE & STORAGE UNIT

When using the optional VGS-1 voice guide & storage unit, you gain access to the
voice recorder and voice announcement functions.

VOICE ANNOUNCEMENTS

When changing modes, frequencies, settings, etc., an audio voice will announce the new information.
1 Enter Menu mode and access Menu 003 (ANN).
2 Set the announcement function to MANUAL, AUTO, or OFF.
· Refer to the tables below for announcements based on settings.

MANUAL:
A microphone PF key must be programmed as [VOICE] to use MANUAL voice announcement.
Operation
Announcement
While in VFO mode Press [VOICE]:
Operating band frequency
While in MR mode Press [VOICE]:
"Channel" + Channel number + operating band frequency
While in Call mode Press [VOICE]:
"Call channel" + operating band frequency
While in Menu mode Press [VOICE]:
Menu number or setting value (some selections have no voice announcement)
While setting up Tone/CTCSS/DCS Press [VOICE]:
Current frequency/code

AUTO:
Announcements are made automatically when changing a mode/frequency/setting.
Operation
Announcement
Press [VFO] VFO
Press [MR] MR
Press [CALL] Call
Press [MENU] Menu + menu number
Press [PM] PM
Press [ENT] Enter
Change the operating band/
turn the power ON
“A”/“B” + “Channel” (for MR only) + “Call”/channel
number + “Channel” (for CALL only) + operating
band frequency + output power level
Change the frequency band New receive frequency
Setting up the PM Channel number/"Off"
Frequency direct entry Entered key number
Memory Direct Entry mode Channel number
Press [F] in VFO mode Memory in + channel number + frequency
Press [F] then [M.IN] in VFO mode + channel number + "Blank
Press [A/B] in VFO mode "B + frequency + output power level
Press [F] and then the Tuning control in VFO mode Menu + menu number
Press the Tuning control in Menu mode Setting value
Perform a Full Reset Full reset?
Perform a Partial Reset Partial reset?
Perform a VFO Reset VFO reset?
Perform a PM Reset PM reset?
Press [LOCK] (to turn the Lock function ON) Lock on
Press [LOCK] (to turn the Lock function OFF) Lock off
Tone frequency setup Tone frequency + frequency value
CTCSS frequency setup CTCSS frequency + frequency value
DCS code setup DCS + code value
MHz step frequency setup MHz Step + frequency value
10 MHz setup + "MHz setup + frequency value
Output power setup TX Power + power level


Voice Announcement Language

1 Enter Menu mode and access Menu 004 (ANN.LNG).
2 Set the language to ENG (English) or JPN (Japanese).

Voice Announcement Volume

1 Enter Menu mode and access Menu 005 (ANN.VOL).
2 Set the announcement volume level from 1 to 7.
· To turn the volume OFF, turn the announcement function OFF.

Voice Announcement Speed

1 Enter Menu mode and access Menu 006 (ANN.SPD).
2 Set the announcement speed level from 0 to 4.
· The speed settings are as follows:
0: 0.85 times normal speed
1: Normal speed
2: 1.15 times normal speed
3: 1.30 times normal speed
4: 1.45 times normal speed

VOICE RECORDER

The voice recorder provides you with 3 VGS channels for recording voice memos,
along with a single VGS channel for recording conversations. You can also
prepare automated message responses to received calls.
Each recording can last for up to 30 seconds.

Voice memos

To record a voice memo, for later playback:
1 Press the PF key programmed as [VGS].
2 Press and hold the key for the VGS channel number you want to store the
memo in: [F] (1), [TONE] (2), or [REV] (3).
· A beep will sound and the transceiver will enter Recording mode.
3 Press and hold the VGS channel number key again (the same key you
pressed in the previous step), then speak into the microphone to record your memo.
· Recording begins as soon as you press the VGS channel number key, and a
timer appears on the display.
· Pressing the microphone PTT switch at this time will transmit your message as
well as record it. Do not press the microphone PTT switch if you do not want to transmit your message.
4 Release the VGS channel number key to end the recording at any time and
store it into the selected VGS channel.
· If the memory becomes full, recording will stop automatically and store the voice memo to memory.
· "WRITING" appears on the display while the recording is being stored to memory.

Conversation Recorder

To record a 30 second conversation:
1 Enter Menu mode and access Menu 009 (CON.REC).
2 Set the Conversation Recorder to ON (or OFF).
· The icon appears on the display when this function is activated. The icon
does not appear during playback, in Repeater mode, or in Remote Control mode.
3 Press the PF key programmed as [VGS].
4 Press [LOW] (4) (1s) to store the conversation in VGS channel 4.

Playback

1 Press the PF key programmed as [VGS].
2 Press the key for the VGS channel number you want to play back: [F] (1),
[TONE] (2), [REV] (3), or [LOW] (4) (when the Conversation Recorder is ON.)
· The recording saved in the channel you selected is played back.
· To end playback at any time, press [PF1] (CLR).
· To exit, press [VGS] again.
· During playback, you can switch to any of recordings 1, 2, 3, or 4 by pressing the appropriate key.
· While playing a recording, you can transmit the recording by pressing the
[PTT] switch. (Continue holding the [PTT] switch until the entire recording is transmitted.)

Playback Repeat

You can set messages to be repeatedly played back.
1 Enter Menu mode and access Menu 007 (PLAY.BK).
2 Set the the Playback Repeat function to ON or OFF.

Playback Repeat Interval

If the Playback Repeat function is activated, you can set a time interval for how
often the memo/message is played back.
1 Enter Menu mode and access Menu 008 (P.BK.INT).
2 Set the interval from 0 to 60 seconds.

CROSS-BAND/ LOCKED-BAND OPERATION (K TYPE MODELS ONLY)

This transceiver is capable of receiving signals on one band and re-transmitting
signals on the other band. This function repeats signals originating from one
band, using the other band. For example, a signal received on band A (VHF) is
retransmitted on band B (UHF). Similarly, a signal received on band B (UHF) is
retransmitted on band A (VHF).

Locked-band Repeater:
The transceiver uses the same band to receive or
transmit a signal. You can set either the A band (A-TX) or B band (B-TX) as the
transmit band.

Cross-band Repeater:
If receiving a signal on the TX band, the transceiver
switches the current RX only band to the TX band. This is useful when joining
in a group talk. Participants in a group talk need to set a receive and transmit
frequency on different bands so as not to miss any conversation within the group.
1 Enter Menu mode and access Menu 403 (RPT.MOD).
2 Set the Repeater operation mode to CROSS (cross-band), A-TX (A band), or
B-TX (B band).
3 Turn the transceiver power OFF.
4 Press [TONE] + Power ON.
· The Repeater mode is ON and the
and icons blink on the display.
· You are unable to perform any transceiver functions while in Repeater mode.
· To return to normal operation, turn the transceiver power OFF, then press [TONE] + Power ON.
Note:
You cannot activate the Repeater function while in single band operating mode or Weather Channel mode.
Activating the Repeater function switches OFF the Automatic Simplex Checker (ASC).
The Time-Out Timer is locked at 3 minutes.
Resetting the transceiver will not cancel the Repeater mode.

REPEATER HOLD

If necessary, you can set the transceiver to remain in the transmit mode for
500 ms after a signal drops.
1 Enter Menu mode and access Menu 404 (RPT.HLD).
2 Set the Repeater Hold function to ON or OFF.

REPEATER ID

If necessary, you can set the transceiver to transmit your call sign every 10 minutes.
1 Enter Menu mode and access Menu 406 (ID.TX).
2 Set the ID Transmit function to OFF, MORSE, or VOICE.
· To use VOICE transmission, you must have the VGS-1 option installed. When using
the VGS-1 option, the ID Transmit function will use VGS channel 3 as the call sign.
· When selecting MORSE, the call sign stored in Menu 405 {see below} will be
transmitted at 20 wpm (words per minute).

Entering your Repeater ID
1 Enter Menu mode and access Menu 405 (RPT.ID).
2 Enter your call sign.

PACKET OPERATION

Connect this transceiver to your personal computer via a Terminal Node
Controller (TNC). You can send messages or commands to far away stations,
obtain a variety of information via your local bulletin boards, or enjoy other Packet
applications. Reference material for starting Packet operation should be available
at any store that handles Amateur Radio equipment.
Note:
When the distance between the radio antenna and your personal computer is too close, interference may occur.
Do not share a power source between the transceiver and the TNC. When the distance
between the TNC and your personal computer is too close, interference may occur.

Data terminal 6 pin DIN connector pins:

Number
Name
I/O
Function
1
PKD
Input
Audio signal for packet transmission
2
DE
-
PKD terminal ground
3
PKS
Input
"L" is transmitted and the microphone is muted
4
PR9
Output
9600 (bps) repeat signal
5
PR1
Output
1200 (bps) repeat signal
6
SQC
Output
Squelch control signal; Closed: "H", Open: "L"
(The default settings can be changed in Menu 520)
 
E
-
Common ground

 

DATA BAND

Select how data will be transmitted and received on your transceiver.
1 Enter Menu mode and access Menu 517 (DAT.BND).
2 Set the data band to A (A band receives and transmits), B (B band receives and
transmits), ATX.BRX (A band transmits and B band receives), or ARX.BTX (A
band receives and B band transmits).

DATA TERMINAL SPEED

Select 1200 or 9600 bps for the data transfer rate, depending on your TNC.

1200 bps:
Transmit data input (PKD) sensitivity is 40 mV peak to peak , and input impedance is 10 k ohms.

9600 bps:
Transmit data input (PKD) sensitivity is 2V peak to peak, input impedance is 10 k, ohms and
the TNC has dual speed capability with a 2V peak to peak output.
1 Enter Menu mode and access Menu 518 (DAT.SPD).
2 Set the data speed to 1200 or 9600 bps.

PC PORT SPEED

You can adjust the speed at which the computer and transceiver exchange
information, when the transceiver is connected to your computer.
1 Enter Menu mode and access Menu 519 (PC.SPD).
2 Set the PC port speed to 9600, 19200, 38400, or 57600 bps.
· Turning the power ON/OFF will change the port speed setting.

SQC OUTPUT SETTING

You can set the condition for which the SQC output terminal becomes active.
1 Enter Menu mode and access Menu 520 (SQC.SRC).
2 Set the SQC output activation method to one of the following:
· OFF: SQC output remains inactive.
· BUSY: When a signal is received on the data band, the SQC output becomes active.
· SQL: While CTCSS/DCS is ON and a matching signal is received, the SQC output
becomes active. While CTCSS/DCS is OFF, the SQC output becomes active when
a busy signal is received.
· TX: While transmitting, the SQC output becomes active.
· BUSY.TX: When the conditions of BUSY and TX (above) are met, the SQC output becomes active.
· SQL.TX: When the conditions of SQL and TX (above) are met, the SQC output becomes active.
Note: The activation type (logic) can be changed using the MCP-2A software.

WIRELESS OPERATION (K TYPE MODELS ONLY)

If you also have a compatible Kenwood handy transceiver, you may use it as a
remote control for this mobile transceiver. You will control one band on the mobile
while sending DTMF tones to the other band from the handheld. This function is
useful, for example, when you want to control the mobile from a location outside
your vehicle.
Note:
As a remote control, you can also use a handy transceiver which does not have a remote
control function but a DTMF function. However, you must manually send DTMF tones for
control code strings. Skip steps 1 and 3 in "PREPARATION".
The FCC rules permit you to send control codes only on the 440 MHz band.

PREPARATION

Let us assume band A (VHF) of the mobile transceiver will be controlled.
On the handy transceiver:
1 Program a 3-digit secret number.
· For the programming method, see the instruction manual for the handheld.
2 Select the transmit frequency on the UHF band.
3 Make the handheld enter Remote Control mode.
· For the method, see the instruction manual for the handheld. If not described, consult your dealer.
On the mobile transceiver:
4 Enter Menu mode and access Menu 522 (REM.ID).
5 Set the ID code to the same secret number you set on the handy transceiver.
6 Select the receive frequency on band B (UHF).
· Match this frequency with the transmit frequency on the handheld.
7 Select band A (VHF) as the TX band or Control band.
8 To cause the mobile to send a control acknowledgment to the handheld, enter
Menu 523 (ANS.BK) and set it to ON.
· DTMF tones which represent the secret number will be used as an acknowledgment.
9 Turn the transceiver power OFF.
10 Press [REV] + Power ON to enter Remote Control mode.
· The (graphic symbol) and icons appear on the display.
· To exit Remote Control operation, turn the transceiver power OFF, then press [REV] + Power ON again.

CONTROL OPERATION

While in Remote Control mode, the DTMF keys of the handheld will function as
shown in the table below. Each time you press the desired key, the handheld will
automatically enter transmit mode and send the corresponding command to the mobile.

Operation
DTMF Command
Access your mobile via the remote unit (where *** is your 3-digit secret number)
A *** #
End access of your mobile via the remote unit
A #
DCS ON
1
Tone ON
2
CTCSS ON
3
DCS OFF (all signaling OFF)
4
Tone OFF (all signaling OFF)
5
CTCSS OFF (all signaling OFF)
6
Call mode ON
7
VFO mode ON
8
Memory mode ON
9
Transmit power (press to toggle between High, Medium, and Low)
0
Frequency (in VFO mode) or Memory channel (in Memory mode) direct entry
A XXXXXXX
DCS code (when DCS is ON) Tone frequency (when Tone is ON),
or CTCSS frequency (when CTCSS is ON), setup
B XXX
Repeater (Cross-band or Locked-band) ON
C
Repeater OFF
D
Step the frequency or Memory channel down
*
Step the frequency or Memory channel up
#

 

TRANSCEIVER RESET

There are 4 types of transceiver reset available:

VFO Reset

Use to initialize the VFO and accompanying settings.

PART (Partial) Reset

Use to initialize all settings other than the Memory channels, the DTMF memory, and the PM channels.

PM Reset

Use to reset only the Programmable Memory channels to their default values.

FULL Reset

Use to initialize all transceiver settings that you have customized.

There are 2 ways to perform a reset on the transceiver: by key operation and by accessing Menu mode.

Key Operation:

1 Turn the transceiver power OFF.
2 Press [F] + Power ON.
3 Rotate the Tuning control and select your desired reset type: VFO, PART, PM, or FULL.
4 Press the Tuning control to set the reset type.
· A confirmation message appears on the display.
· Press [TONE] (BACK) to return to the previous display or [F] (ESC) to cancel the reset.
5 Press the Tuning control again to perform the reset.
Note: When in Remote Control or Repeater mode, you cannot reset the transceiver using the Key Operation method.

Menu Mode:
1 Enter Menu mode and access Menu 999 (RESET).
2 Set the reset type to VFO, PART, PM, or FULL.
3 Press the Tuning control to set the reset type.
· A confirmation message appears on the display.
· Press [TONE] (BACK) to return to the previous display or [F] (ESC) to cancel the reset.
4 Press the Tuning control again to perform the reset.
Note: When the Channel Display function or Key Lock function is ON, the transceiver reset cannot be performed.

OPTIONS

The following options are available for use with this transceiver:
· DFK-3D
Detachable Front Panel Kit (3 m)
· PG-3B
Noise Filter
· MC-45
Microphone
· PG-5A
Data Cable
· MC-59
Microphone with keypad
· PG-5G
Programming Interface Cable
· MCP-2A
Memory Control Program (2 m) (web download software)
· PG-5H
PC Interface Cable Kit (2 m)
· MJ-88
Microphone Plug Adapter
· PG-5F
Extension Cable Kit (4 m)
· MJ-89
Modular Plug Microphone
· PS-33
DC Power Supply Switch
· PS-53
DC Power Supply
· PG-2N
DC Cable (2 m)
· SP-50B
External Speaker
· PG-20
DC Cable (7 m)
· VGS-1
Voice Guide & Storage Unit

Note:
Optional accessories for use with this transceiver may change, post-production. (New
options may become available and/or current options may be discontinued.) Please refer to the
options catalog(s) for applicable transceivers.

MEMORY CONTROL PROGRAM MCP-2A

The following functions can be set only by using the MCP-2A software:
· SQC active condition
· Microphone sensitivity level
· 10 MHz mode selection
· Power on password value
Using the MCP-2A software, you can:
· View memory channel groups
· Name memory groups
· Name PM channels
· Save/load settings
· Read exported TravelPlus for RepeatersTM files issued from the ARRLTM
· Print/export memory and various settings in html
(TravelPlus for Repeaters is a trademark of ARRL.)
To download the MCP-2A software, go to:
http://www.kenwood.com/i/products/info/amateur.html
Note: This URL may change without notice.

Using the McP-2a Software

1 Follow the directions of the installer to install the software.
2 Set up the PC COM port and baud rate.
3 The transceiver data is read from the MCP-2A software.
4 Select your desired settings, then write the data to the transceiver.

CONNECTING THE PG-5G/ PG-5H INTERFACE CABLES

The PG-5G package comes with the serial communications cable only.
The PG-5H packages come with the following two cables:
Data communications cable
· 6 Pin DIN to 2 1/8" mono plugs to connect To PC audio terminal
Serial communications cable
· 8 Pin DIN To PC 9-pin D-SUB connector to connect to PC terminal

PC terminal pins

Number
Name
I/O
Function
1
RTS
Output
Request to Send
2
CTS
Input
Clear to Send
3
TXD
Output
Transmit Data
4
GND
-
GND
5
RXD
Input
Receive Data
6
NC
-
-
7
NC
-
-
8
NC
-
-


INSTALLING THE DFK-3D PANEL KIT

Installing the Sub-Panel

1 Detach the front operation panel from the
base unit, then remove the modular cable from both sides.
2 Connect the 4-pin connector of the supplied modular cable to the operation panel.
· Align the cable with the cable guide.
3 Connect the supplied sub-panel to the sub-panel
· Install the sub-panel in a manner so as not to disrupt the cable.
4 Connect the 8-pin connector of the supplied modular cable to the base unit.
· The line filter is pre-installed onto the cable.

Installing the Panel bracket

1 Clean and dry the installation location.
Do not install the bracket close to an air bag.
2 Remove the release paper from the base self-tapping screw
of the panel bracket, then secure it in place using the 3 supplied self-tapping screws.
· Allow the panel to set for a while, to ensure it
remains fast. Otherwise, vibrations may occur.
· After removing the release paper, it cannot be reused.
3 Attach the panel holder to the base bracket panel holder using the 2 supplied SEMS screws.
4 Attach the operation panel to the panel holder so that it locks in place.

CONNECTING THE PG-5F EXTENSION CABLE

If necessary, the PG-5F extension cable kit can be used with the DFK-3D panel
kit. Using two PG-5F kits, you can extend the cables to the maximum length.
(Components marked with an asterisk * are included in the PG-5F kit.)
* DC power cables (6 m)
External speaker cables (4 m)
* Modular Microphone extension cable (4 m)
* Extension connectors
* Modular Remote Head extension cable (4 m)
* Line Filters

connecting Using a Single extension Kit

external speakers are extended using a speaker extension cable.
microphone is extended using an extension cable with extension connector and line filter.
* DC power cables (6 m)
operation panel is extended using an extension cable with extension connector and line filter.
12 Volt DC cable is extended using the 6 meter DC power cable.

connecting Using Two extension Kits

Identical to using a single extension kit but two modular extension cables and
extension connectors are used to connect the microphone and operation panel.

Installing the line filter

Install the line filter approximately 3 cm from the connector which attaches to the base unit.

affixing the Microphone cable

Lock the microphone cable down using two self tapping screws, flat washers,and cable clamps.
One on either side of the connector. with the connector resting on the cushion pad.

INSTALLING THE VGS-1 UNIT

Follow the instructions below to install the VGS-1 unit.
1 Remove the 8 screws from the cover of the base unit, then remove the cover itself from the unit.
2 From the 5 black cushions supplied with the VGS-1, select the thickest rectangular
cushion (20 x 30 x 12 mm) and attach it to the top surface of the VGS-1 unit.
· To prevent interference to the terminal of the VGS-1, ensure that you attach the thick
square cushion to the base plate surface.
3 From the remaining cushions, select the thickest square cushion (21 x 21 x 2.5
mm) and attach it to the printed circuit board.
· The remaining cushions are not used with this transceiver.
· Ensure that the cushion is placed within the
guidelines on the PCB.
4 Insert the VGS-1 unit into the connector on the transceiver.
· Press down on the top of the VGS-1 unit to ensure that it is securely attached to the connector.
5 Replace the cover on the base unit and secure it using the 8 screws.

MAINTENANCE

GENERAL INFORMATION

This product has been factory aligned and tested to specification before shipment.
Attempting service or alignment without factory authorization can void the product warranty.

SERVICE

When returning this product to your dealer or service center for repair, pack it in
its original box and packing material. Include a full description of the problem(s)
experienced. Include your telephone number along with your name and address
in case the service technician needs to contact you; if available, also include your
fax number and e-mail address. Don't return accessory items unless you feel
they are directly related to the service problem.
You may return this product for service to the authorized Kenwood dealer from
whom you purchased it, or any authorized Kenwood service center. Please do
not send subassemblies or printed circuit boards; send the complete product. A
copy of the service report will be returned with the product.

SERVICE NOTE

If you desire to correspond on a technical or operational problem, please make
your note legible, short, complete, and to the point. Help us help you by providing
the following:
· Model and serial number of equipment
· Question or problem you are having
· Other equipment in your station pertaining to the problem
Do not pack the equipment in crushed newspapers for shipment! Extensive damage may result
during rough handling or shipping.
Note:
Record the date of purchase, serial number and dealer from whom this product was purchased.
For your own information, retain a written record of any maintenance performed on this product.
When claiming warranty service, please include a photocopy of the bill of sale or other
proof-of-purchase showing the date of sale.

CLEANING

To clean the case of this product, use a neutral detergent (no strong chemicals) and a damp cloth.

TROUBLESHOOTING

The problems described in this table are commonly encountered operational
malfunctions and are usually not caused by circuit failure.

Problem
Probable Cause
Corrective Action
The transceiver will
not power up after
connecting a 13.8 V
DC power supply and
pressing [ ]. Nothing
appears on the display.
1 The power cable
was connected
backwards.

2 One or more of the
power cable fuses
are open
1 Connect the supplied DC
power cable correctly (red
to + terminal and black to
– terminal).

2 Look for the cause of
the blown fuse(s). After
inspecting and correcting
any problems, install a
new fuse(s) with the same
ratings.
The frequency cannot
be selected by turning
the Tuning control or
by pressing microphone
[UP]/[DWN].
Memory Recall was
selected.
Press [VFO].
Most keys and the
Tuning control do not
function.
1 One of the Lock
functions is ON.

2 The transceiver is
in Channel Display
mode.
1 Unlock all of the Lock
functions.

2 With the transceiver
power OFF, press [REV] +
Power ON to exit Channel
Display mode.
Memory channels
cannot be selected
by turning the Tuning
control or by pressing
microphone [UP]/[DWN].
No data has been stored
in any Memory channel.
Store data in some Memory
channels.
You cannot transmit
even though you are
pressing [PTT].
1 The microphone plug
was not inserted
completely into the
transceiver.

2 You selected a
transmit offset that
places the transmit
frequency outside the
allowable range.

3 The external TNC is
transmitting.
1 Switch the power OFF,
then insert the microphone
plug until the locking tab
clicks in place.

2 Turn the offset shift
function OFF.

3 Press [PTT] after the TNC
has finished transmitting.

 



SPECIFICATIONS

Specifications are subject to change without notice due to advancements in technology.

General
TM-V71A
K Type
TM-V71A
E Type
TM-V71E
M4 Type
Guaranteed
range
Band
A & B
TX & RX
144 ~ 148 MHz
144 ~ 146 MHz
438 ~ 450 MHz
430 ~ 440 MHz
Frequency
range
Band A
RX
118 ~ 524 MHz
Band B
136 ~ 524 MHz
800 ~ 1300 MHz
(excluding cellular band)
Mode
F2D/ F3E
Antenna impedance
50 ohms
Operating temperature range
–20°C ~ +60°C (–4°F ~ +140°F)
Power requirement
13.8V DC ±15% (Negative ground)
Frequency stability
Within ±5 ppm (–10°C ~ +50°C)
Current TX VHF Hi
Less than 13.0 A
Mid
Less than 5.5 A
Less than 9.0 A
Low
Less than 4.0 A
UHF Hi
Less than 13.0 A
Mid
Less than 6.5 A
Less than 9.0 A
Low
Less than 5.0 A
RX
Less than 1.2 A (at 2W audio output)
Dimensions
(W x H x D)
Without projections
Panel: 140 x 43 x 38.2 mm (5.51" x 1.69" x 1.50")
Body (with Panel): 140 x 43 x 180.7 mm (5.51" x 1.69" x 7.11")
With projections
Panel: 140 x 43 x 55.4 mm (5.51" x 1.69" x 2.18")
Body (with Panel): 140 x 43 x 213.1 mm (5.51" x 1.69" x 8.39")
Weight (approx.)
Body (with Panel): 1.5 kg (3.3 lbs)

 

Transmitter
TM-V71A
K Type
TM-V71A
E Type
TM-V71E
M4 Type
RF power
output
Hi
50 W
Mid
Approx. 10 W
25W
Low
Approx. 5 W
Modulation
Reactance modulation
Maximum frequency deviation
Within ±5 kHz
Spurious radiation
Less than –60 dB
Modulation distortion
(300 Hz ~ 3 kHz)
Less than 3%
Microphone impedance
600 Ohms

 

Receiver
TM-V71A
K Type
TM-V71A
E Type
TM-V71E
M4 Type
Circuitry
Double super heterodyne
Intermediate
frequency
1st (Band A/ Band B)
45.05 MHz/ 49.95 MHz
2nd (Band A/ Band B)
455 kHz/ 450 kHz
Sensitivity
Less than 0.16 μV
Squelch sensitivity
Less than 0.1 μV
Selectivity –6 dB
More than 11 kHz
–50 dB
Less than 30 kHz
Low frequency output (8 Ω)
More than 2 W (at 5% distortion)


Concerning the received frequency display, an un modulated signal may be received.
This is according to the set intrinsic frequency form.
VxU reception
(A band) (144 MHz + 45.05 MHz) x 2 minus
(B band) (430 MHz - 49.95 MHz) =
45.05 MHz, 49.95 MHz

(A band) (144 MHz + 45.05 MHz) x 4 minus
(B band) (430 MHz - 49.95 MHz) x 2 =
45.05 MHz, 49.95 MHz

UxV reception
(A band) (430 MHz - 45.05 MHz) minus
(B band) (144 MHz + 49.95 MHz) x 2 =
45.05 MHz, 49.95 MHz

(A band) (430 MHz - 45.05 MHz) x 2 minus
(B band) (144 MHz + 49.95 MHz) x 4 =
45.05 MHz, 49.95 MHz

MANUAL FRONT COVER

KENWOOD

INSTRUCTION MANUAL
144/440 MHz FM DUAL BANDER
TM-V71A
144/430 MHz FM DUAL BANDER
TM-V71A/ TM-V71E

This equipment complies with the essential requirements of Directive 1999/5/EC.
The use of the warning symbol (graphic symbol) means the equipment is subject to restrictions of use in certain countries.
This equipment is intended for use in all EU countries and CH, LI, IS and NO, and requires a license.

© B62‑1926‑00 (K, E, M4)
09 08 07 06 05 04 03 02 01 00

Thank You

We are grateful you decided to purchase this Kenwood FM transceiver.
Kenwood always provides Amateur Radio products which surprise and excite
serious hobbyists. This transceiver is no exception. Kenwood believes that this
product will satisfy your requirements for both voice and data communications.

Features

This transceiver has the following main features:
• Enhanced Programmable Memory (PM) channels store virtually entire current operating environments for your quick recall.
• Contains a total of 1000 Memory channels to program frequencies and other various
data. Allows each Memory channel to be named using up to 6 alphanumeric characters.
• Continuous Tone Coded Squelch System (CTCSS) or Digital Code Squelch (DCS) rejects unwanted calls from other stations.
Writing Conventions Followed in this Manual
The writing conventions described below have been followed to simplify instructions and avoid unnecessary repetition.

Instruction
Action
Press [KEY]. Momentarily press KEY.
Press [KEY] (1s). Press and hold KEY for 1 second or longer.
Press [KEY1], [KEY2]. Press KEY1 momentarily, release KEY1,
then press KEY2.
Press [F], [KEY]. Press the F key to enter Function mode,
then press KEY to access its secondary function.
Press [KEY] + Power ON. With the transceiver power OFF, press and
hold KEY while turning the transceiver power ON.

 

Information on Disposal of Old Electrical and Electronic Equipment (applicable for EU
countries that have adopted separate waste collection systems)
Products with the symbol (crossed-out wheeled bin) cannot be disposed as household waste.
Old electrical and electronic equipment should be recycled at a facility capable of handling these items
and their waste byproducts. Contact your local authority for details in locating a recycle facility nearest
to you. Proper recycling and waste disposal will help conserve resources whilst preventing detrimental
effects on our health and the environment.

 

Notices to the User

One or more of the following statements may be applicable:
FCC WARNING
This equipment generates or uses radio frequency energy. Changes or modifications to this
equipment may cause harmful interference unless the modifications are expressly approved in the
instruction manual. The user could lose the authority to operate this equipment if an unauthorized
change or modification is made.

INFORMATION TO THE DIGITAL DEVICE USER REQUIRED BY THE FCC

This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation.
This equipment generates, uses and can generate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that the interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer for technical assistance.

WHEN CONDENSATION OCCURS INSIDE THE TRANSCEIVER

Condensation may occur inside the transceiver in such a case where the room is warmed using a
heater on cold days or where the transceiver is quickly moved from a cold room to a warm room.
When condensation occurs, the microcomputer and/or the transmit/receive circuits may become
unstable, resulting in transceiver malfunction. If this happens, turn OFF the transceiver and just
wait for a while. When the condensation droplets disappear, the transceiver will function normally.

WARNING!

• EXPLOSIVE ATMOSPHERES (GASES, DUST, FUMES, etc.)
Turn OFF your transceiver while taking on fuel or while parked in gasoline service stations. Do
not carry spare fuel containers in the trunk of your vehicle if your transceiver is mounted in the trunk area.

• INJURY FROM RADIO FREQUENCY TRANSMISSIONS
Do not operate your transceiver when somebody is either standing near to or touching the
antenna, to avoid the possibility of radio frequency burns or related physical injury.

• DYNAMITE BLASTING CAPS
Operating the transceiver within 150 m (500 feet) of dynamite blasting caps may cause them
to explode. Turn OFF your transceiver when in an area where blasting is in progress, or where
“TURN OFF TWO-WAY RADIO” signs have been posted. If you are transporting blasting caps
in your vehicle, make sure they are carried in a closed metal box with a padded interior. Do not
transmit while the caps are being placed into or removed from the container.


Precautions

Observe the following precautions to prevent fire, personal injury, and transceiver damage.
• When operating mobile, do not attempt to configure the transceiver while driving; it is too dangerous.
• Do not transmit with high output power for extended periods. The transceiver may overheat.
• Do not disassemble or modify the transceiver for any reason, unless instructed by this
manual or by Kenwood documentation.
• Do not expose the transceiver to long periods of direct sunlight, nor place it near heating appliances.
• Do not place the transceiver in excessively dusty, humid, or wet areas, nor on unstable surfaces.
• If an abnormal odor or smoke is detected coming from the transceiver, switch the
transceiver power off immediately, and contact a Kenwood service station or your dealer.
• Use of the transceiver while you are driving may be against traffic laws. Please check
and observe the vehicle regulations in your area.
• Do not use options not specified by Kenwood.

CAUTION!

• The transceiver is designed for a 13.8V DC (±15%) power source! Never use a 24V battery
to power the transceiver. Check the battery polarity and voltage of the vehicle before installing the transceiver.
• Use only the supplied DC power cable or a Kenwood optional DC power cable.
• Do not insert metal objects into the cooling fan.

WARNING!

• Do not cut and/or remove the fuse holder on the DC power cable. Improper connections and/or
current surges may cause smoke or fire.
• For passenger safety, install the transceiver securely using the supplied mounting bracket and
screw set so the transceiver will not break loose in the event of a collision.
• Various electronic equipment in your vehicle may malfunction if they are not properly protected
from the radio frequency energy which is present while transmitting. Electronic fuel injection,
anti-skid braking, and cruise control systems are typical examples of equipment that may
malfunction. If your vehicle contains such equipment, consult the dealer for the make of
vehicle and enlist his/her aid in determining if they will perform normally while transmitting.

Disclaimer and Notes From the Author (K6DQ)

This document has been slightly re-arranged and modified to facilitate better interpretation
by software screen readers for the blind and visually impaired. All graphic images have been
removed and textual descriptions have been added where deemed necessary for clarification.
All page numbers and references to them have also been removed.
Last updated: 09/20/2020

 

End of Document